文献速递肿瘤 PET/CT

基于放射组学[18F]FDG PET/CT特征的机器学习鉴别滤泡性淋巴瘤与弥漫大B细胞淋巴瘤

Machine learning in the differentiation of follicular lymphoma from diffuse large B-cell lymphoma with radiomic [18F]FDG PET/CT features.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2021-12-01

本研究纳入经病理确诊的原发性滤泡性淋巴瘤(FL,n=44)和弥漫大B细胞淋巴瘤(DLBCL,n=76)患者,从基线[18F]FDG PET/CT提取放射组学特征并用机器学习分类器分析。Gradient Boosting分类器使用136个放射组学特征鉴别FL与DLBCL病灶的AUC为0.86、准确率80%,优于基于SUVmax的logistic回归模型(AUC 0.79、准确率70%),差异有统计学意义(p≤0.01)。

要点

  • Gradient Boosting分类器使用136个放射组学特征鉴别FL与DLBCL病灶,AUC 0.86、准确率80%。
  • 基于SUVmax的logistic回归模型AUC 0.79、准确率70%。
  • Gradient Boosting分类器的AUC和准确率均显著高于SUVmax模型(p≤0.01)。

核心结论

  • 放射组学特征的机器学习分析对鉴别FL与DLBCL肿瘤病灶可能具有诊断价值,超越单独使用SUVmax。

研究设计与样本

  • 基于病理确诊的原发性FL(n=44)或DLBCL(n=76)患者,选取诊断后6个月内具有EARL重建参数的[18F]FDG PET/CT。
  • 从共配准的[18F]FDG PET和CT图像感兴趣体积中提取放射组学特征。
  • 使用基于logistic回归和树集成分类器(AdaBoosting、Gradient Boosting和XG Boosting)的机器学习分类器分析所选放射组学特征。
  • 将放射组学特征的性能与基于SUVmax的logistic回归模型进行比较。

主要发现

  • 从分割病灶中纳入121个FL和227个DLBCL病灶进行放射组学特征提取。
  • 共从SUVmap提取79个放射组学特征、从CT提取51个特征以及6个形状特征。
  • Gradient Boosting分类器使用136个放射组学特征达到最佳鉴别性能,AUC为0.86、准确率80%。
  • 基于SUVmax的logistic回归模型AUC为0.79、准确率70%。
  • Gradient Boosting分类器的AUC和准确率显著高于基于SUVmax的logistic回归(p≤0.01)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: One of the challenges in the management of patients with follicular lymphoma (FL) is the identification of individuals with histological transformation, most commonly into diffuse large B-cell lymphoma (DLBCL). [18F]FDG-PET/CT is used for staging of patients with lymphoma, but visual interpretation cannot reliably discern FL from DLBCL. This study evaluated whether radiomic features extracted from clinical baseline [18F]FDG PET/CT and analyzed by machine learning algorithms may help discriminate FL from DLBCL. MATERIALS AND METHODS: Patients were selected based on confirmed histopathological diagnosis of primary FL (n=44) or DLBCL (n=76) and available [18F]FDG PET/CT with EARL reconstruction parameters within 6 months of diagnosis. Radiomic features were extracted from the volume of interest on co-registered [18F]FDG PET and CT images. Analysis of selected radiomic features was performed with machine learning classifiers based on logistic regression and tree-based ensemble classifiers (AdaBoosting, Gradient Boosting, and XG Boosting). The performance of radiomic features was compared with a SUVmax-based logistic regression model. RESULTS: From the segmented lesions, 121 FL and 227 DLBCL lesions were included for radiomic feature extraction. In total, 79 radiomic features were extracted from the SUVmap, 51 from CT, and 6 shape features. Machine learning classifier Gradient Boosting achieved the best discrimination performance using 136 radiomic features (AUC of 0.86 and accuracy of 80%). SUVmax-based logistic regression model achieved an AUC of 0.79 and an accuracy of 70%. Gradient Boosting classifier had a significantly greater AUC and accuracy compared to the SUVmax-based logistic regression (p≤0.01). CONCLUSION: Machine learning analysis of radiomic features may be of diagnostic value for discriminating FL from DLBCL tumor lesions, beyond that of the SUVmax alone.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. de Jesus FM, Yin Y, Mantzorou-Kyriaki E, et al. Machine learning in the differentiation of follicular lymphoma from diffuse large B-cell lymphoma with radiomic [18F]FDG PET/CT features. Eur J Nucl Med Mol Imaging. 2021. PMID: 34850248. doi:10.1007/s00259-021-05626-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。