本研究通过仿真和21例受试者(14名健康志愿者、7名癌症患者)的60分钟动态全身18F-FDG PET数据,评估脉冲定时方法(前沿法LE与恒比定时甄别)估计和校正延迟的效果。仿真显示10% LE阈值在2秒帧长下偏差与标准差可接受;汇总ROI分析(n=154)显示LE(10%阈值)与联合估计法在延迟及动力学参数上高度一致。结论认为LE延迟校正可作为联合估计的高效替代,计算时间仅为其一小部分。

要点

  • 仿真中10% LE阈值在2秒帧长下偏差与标准差处于可接受水平。
  • 汇总ROI(n=154)中LE与联合估计法估计延迟的Pearson r=0.96(P<0.001)。
  • 未做延迟校正时,最小延迟组织汇总分析中vb降低69.4%、K1降低4.8%。

核心结论

  • 本研究证明了延迟校正在全身PET中的重要性。
  • LE延迟校正可作为联合估计的高效替代方法,所需计算时间仅为其一小部分,并可在全身PET数据集中对超过10^6个体素快速完成延迟校正。

研究设计与样本

  • 仿真研究设置不同延迟值、帧长和噪声水平,测试前沿法(LE)与恒比定时甄别两种脉冲定时方法及其阈值的耐受性。
  • 方法应用于21例受试者(14名健康志愿者、7名癌症患者)的60分钟动态全身18F-FDG PET采集数据。
  • 进行感兴趣区(ROI)动力学分析并生成参数图像,比较LE与联合估计(JE)延迟校正方法以及不做延迟校正的情况。

主要发现

  • 仿真显示10% LE阈值在所有测试噪声水平下、采用2秒帧长时,偏差与标准差处于可接受水平。
  • 汇总ROI结果(n=154)显示LE(10%阈值)与JE法在估计延迟上高度一致(Pearson r=0.96,P<0.001)。
  • LE与JE法在动力学参数vb(r=0.96,P<0.001)、Ki(r=1.00,P<0.001)和K1(r=0.97,P<0.001)上高度一致。
  • 排除延迟极小的组织后,未做延迟校正时汇总分析中vb降低69.4%、K1降低4.8%。
  • 参数图像获得类似结果;此外,与不做延迟校正及Patlak分析相比,LE和JE延迟校正总体上改善了病灶Ki对比度。

关键数值与推荐

  • 仿真中10% LE阈值在2秒帧长下偏差与标准差处于可接受水平。
  • LE(10%阈值)与JE法估计延迟的Pearson r=0.96(P<0.001)。
  • LE与JE法估计vb的Pearson r=0.96(P<0.001)、Ki的r=1.00(P<0.001)、K1的r=0.97(P<0.001)。
  • 未做延迟校正时,最小延迟组织汇总分析中vb降低69.4%、K1降低4.8%。

临床怎么用

  • LE延迟校正可作为JE的高效替代,所需计算时间仅为JE的一小部分,并可在全身PET数据集中对超过10^6个体素快速完成延迟校正。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Quantitative kinetic modeling requires an input function. A noninvasive image-derived input function (IDIF) can be obtained from dynamic PET images. However, a robust IDIF location (e.g., aorta) may be far from a tissue of interest, particularly in total-body PET, introducing a time delay between the IDIF and the tissue. The standard practice of joint estimation (JE) of delay, along with model fitting, is computationally expensive. To improve the efficiency of delay correction for total-body PET parametric imaging, this study investigated the use of pulse timing methods to estimate and correct for delay. Methods: Simulation studies were performed with a range of delay values, frame lengths, and noise levels to test the tolerance of 2 pulse timing methods-leading edge (LE) and constant fraction discrimination and their thresholds. The methods were then applied to data from 21 subjects (14 healthy volunteers, 7 cancer patients) who underwent a 60-min dynamic total-body 18F-FDG PET acquisition. Region-of-interest kinetic analysis was performed and parametric images were generated to compare LE and JE methods of delay correction, as well as no delay correction. Results: Simulations demonstrated that a 10% LE threshold resulted in biases and SDs at tolerable levels for all noise levels tested, with 2-s frames. Pooled region-of-interest-based results (n = 154) showed strong agreement between LE (10% threshold) and JE methods in estimating delay (Pearson r = 0.96, P < 0.001) and the kinetic parameters vb (r = 0.96, P < 0.001), Ki (r = 1.00, P < 0.001), and K1 (r = 0.97, P < 0.001). When tissues with minimal delay were excluded from pooled analyses, there were reductions in vb (69.4%) and K1 (4.8%) when delay correction was not performed. Similar results were obtained for parametric images; additionally, lesion Ki contrast was improved overall with LE and JE delay correction compared with no delay correction and Patlak analysis. Conclusion: This study demonstrated the importance of delay correction in total-body PET. LE delay correction can be an efficient surrogate for JE, requiring a fraction of the computational time and allowing for rapid delay correction across more than 106 voxels in total-body PET datasets.