文献速递心脏核医学

心脏再同步化治疗后肺灌注与纽约心脏协会分级改善

Pulmonary perfusion and NYHA classification improve after cardiac resynchronization therapy.
PubMed 文献 · J Nucl Cardiol · 2021-11-08

本研究纳入19例接受心脏再同步化治疗(CRT)的心力衰竭患者,在CRT前后行通气/灌注单光子发射计算机断层扫描(V/P SPECT)、超声心动图、纽约心脏协会(NYHA)分级及明尼苏达心力衰竭生活质量问卷(MLWHF)评估。CRT后V/P SPECT灌注梯度改善与NYHA分级改善相关(P=0.0456),而超声心动图左室收缩末期容积(LVESV)改善与NYHA改善无关;LVESV改善患者比例(7/19,37%)低于灌注梯度改善比例(13/19,68%);灌注梯度与LVESV变化均与MLWHF变化无关(P=1.0)。

要点

  • CRT后V/P SPECT灌注梯度改善与NYHA分级改善相关(P=0.0456)。
  • CRT后LVESV改善与NYHA分级改善无关。
  • 灌注梯度改善患者比例(13/19,68%)高于LVESV改善比例(7/19,37%)。

核心结论

  • V/P SPECT灌注梯度测量是评估心力衰竭患者CRT反应的一种有前景的、定量的、不依赖操作者的左侧充盈压替代指标。

研究设计与样本

  • 研究纳入19例接受CRT的心力衰竭患者,在CRT前后行V/P SPECT、超声心动图、NYHA分级和MLWHF评估。

主要发现

  • CRT导致V/P SPECT灌注梯度改善,且与NYHA分级改善相关(P=0.0456)。
  • 超声心动图LVESV改善与NYHA分级改善无关。
  • CRT后LVESV改善患者比例为7/19(37%),低于灌注梯度改善比例13/19(68%)。
  • 灌注梯度变化和LVESV变化均与MLWHF变化无关(P=1.0)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Evaluation of cardiac resynchronization therapy (CRT) often includes New York Heart Association (NYHA) classification, and echocardiography. However, these measures have limitations. Perfusion gradients from ventilation/perfusion single-photon emission computed tomography (V/P SPECT) are related to left-heart filling pressures and have been validated against invasive right-heart catheterization. The aim was to assess if changes in perfusion gradients are associated with improvements in heart failure (HF) symptoms after CRT, and if they correlate with currently used diagnostic methods in the follow-up of patients with HF after receiving CRT. METHODS AND RESULTS: Nineteen patients underwent V/P SPECT, echocardiography, NYHA classification, and the quality-of-life scoring system "Minnesota living with HF" (MLWHF), before and after CRT. CRT caused improvement in perfusion gradients from V/P SPECT which were associated with improvements in NYHA classification (P = .0456), whereas improvements in end-systolic volume (LVESV) from echocardiography were not. After receiving CRT, the proportion of patients who improved was lower using LVESV (n = 7/19, 37%) than perfusion gradients (n = 13/19, 68%). Neither change in perfusion gradients nor LVESV was associated with changes in MLWHF (P = 1.0, respectively). CONCLUSIONS: Measurement of perfusion gradients from V/P SPECT is a promising quantitative user-independent surrogate measure of left-sided filling pressure in the assessment of CRT response in patients with HF.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Al-Mashat M, Borgquist R, Carlsson M, et al. Pulmonary perfusion and NYHA classification improve after cardiac resynchronization therapy. J Nucl Cardiol. 2021. PMID: 34750725. doi:10.1007/s12350-021-02848-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。