本研究纳入17例慢性肾脏病-矿物质和骨异常患者,比较动态与静态全身[18F]NaF PET/CT分析骨血浆清除率的方法,静态分析采用半群体输入函数。Patlak分析所得Ki与非线性回归分析所得Ki相关性良好但数值较低;静态全身扫描所得Ki与动态非线性回归所得Ki无显著差异(p=0.29)。结论认为静态扫描可用于未来测量Ki,但结果不应与动态分析结果不加批判地比较。

要点

  • Patlak分析所得Ki与非线性回归分析所得Ki相关性良好,但Patlak分析所得Ki较低。
  • 静态全身扫描所得Ki与动态非线性回归分析所得Ki无显著差异(p=0.29)。
  • 静态[18F]NaF PET/CT扫描可用于未来研究测量CKD-MBD患者的Ki,但结果不应与动态分析结果不加批判地比较。

核心结论

  • 静态全身扫描测得的骨血浆清除率与动态分析测得的清除率数据相关。
  • 静态[18F]NaF PET/CT扫描可应用于未来研究测量CKD-MBD患者的Ki,但结果不应与动态扫描分析所得结果不加批判地比较。

研究设计与样本

  • 17例慢性肾脏病-矿物质和骨异常(CKD-MBD)患者接受60分钟动态扫描,随后接受30分钟静态全身扫描。
  • 采用非线性回归和Patlak分析对四个胸椎的示踪剂动力学进行分析,使用图像衍生的动脉输入函数。
  • 静态全身扫描采用简化Patlak方法分析,仅需单个数据点并结合固定y截距值(V0),两者均通过半群体函数获得。
  • 半群体函数由先前推导的群体输入函数与静脉血样数据组合构建。
  • 将半群体输入函数获得的静态全身扫描分析数据与动态输入函数获得的配对数据进行比较。

主要发现

  • Patlak分析所得骨血浆清除率(Ki)与非线性回归分析所得Ki相关性良好,但Patlak分析所得Ki低于非线性回归分析所得Ki。
  • 静态全身扫描所得Ki与动态扫描采用非线性回归分析所得Ki之间无显著差异(p=0.29)。

临床怎么用

  • 原文结论认为静态[18F]NaF PET/CT扫描可应用于未来研究测量CKD-MBD患者的Ki,但结果不应与动态扫描分析结果不加批判地比较。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The purpose of this study is to compare dynamic and static whole-body (WB) [18F]NaF PET/CT scan methods used for analysis of bone plasma clearance in patients with chronic kidney disease-mineral and bone disorder (CKD-MBD). METHODS: Seventeen patients with CKD-MBD underwent a 60-min dynamic scan followed by a 30-min static WB scan. Tracer kinetics in four thoracic vertebrae were analysed using nonlinear regression and Patlak analysis using image-derived arterial input functions. The static WB scan was analysed using a simplified Patlak method requiring only a single data point in combination with a fixed y-intercept value (V0), both obtained using a semi-population function. The semi-population function was constructed by combining a previously derived population input function in combination with data from venous blood samples. Static WB scan analysis data, obtained from the semi-population input functions, was compared with paired data obtained using dynamic input functions. RESULTS: Bone plasma clearance (Ki) from Patlak analyses correlated well with nonlinear regression analysis, but Ki results using Patlak analysis were lower than Ki results using nonlinear regression analysis. However, no significant difference was found between Ki obtained by static WB scans and Ki obtained by dynamic scans using nonlinear regression analysis (p = 0.29). CONCLUSION: Bone plasma clearance measured from static WB scans correlates with clearance data measured by dynamic analysis. Static [18F]NaF PET/CT scans can be applied in future studies to measure Ki in patients with CKD-MBD, but the results should not be compared uncritically with results obtained by dynamic scan analysis.

来源:EJNMMI Res,查看原文。版权归原作者所有。

引用

  1. Vrist MH, Bech JN, Lauridsen TG, et al. Comparison of [18F] NaF PET/CT dynamic analysis methods and a static analysis method including derivation of a semi-population input function for site-specific measurements of bone formation in a population with chronic kidney disease-mineral and bone disorder. EJNMMI Res. 2021. PMID: 34807325. doi:10.1186/s13550-021-00859-7