文献速递肿瘤 PET/CT

基于体素水平房室建模策略的癌症全身PET多参数成像

Total-Body PET Multiparametric Imaging of Cancer Using a Voxelwise Strategy of Compartmental Modeling.
PubMed 文献 · J Nucl Med · 2021-11-18

研究纳入5例转移性癌症患者和5名健康志愿者,在全身PET/CT系统注射370 MBq 18F-FDG后采集60分钟动态数据,比较传统单一不可逆两组织房室模型与体素水平模型选择策略对全身多参数成像的影响。结果显示时间延迟校正对各器官和病灶的动力学定量有不可忽视的影响,体素水平模型选择可克服标准两组织房室模型Ki参数成像中的血管区域伪影。

要点

  • 时间延迟校正对各器官和病灶的动力学定量有不可忽视的影响,血容量较高的病灶中影响更大。
  • 标准两组织房室模型进行Ki参数成像会引入血管区域伪影,体素水平模型选择策略可克服该伪影。
  • 不同器官和病灶的时间延迟与适宜动力学模型不同,建模时间延迟和模型选择可改善全身多参数成像。

核心结论

  • 不同器官和病灶的时间延迟与适宜动力学模型存在差异,对血输入函数时间延迟建模并进行模型选择可改善全身多参数成像。

研究设计与样本

  • 研究纳入10名受试者(5例转移性癌症患者和5名健康志愿者),在全身PET/CT系统注射370 MBq 18F-FDG后采集60分钟动态数据。
  • 采用两种方法进行全身参数成像:传统方法使用单一不可逆两组织房室模型(分别在有和无时间延迟校正下),第二种方法为每个体素从3个候选模型中选出最佳动力学模型。

主要发现

  • 时间延迟校正对各器官和病灶的动力学定量有不可忽视的影响,在血容量较高的病灶中影响更大。
  • 使用标准两组织房室模型进行Ki参数成像会引入血管区域伪影,体素水平模型选择策略可克服该伪影。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Quantitative dynamic PET with compartmental modeling has the potential to enable multiparametric imaging and more accurate quantification than static PET imaging. Conventional methods for parametric imaging commonly use a single kinetic model for all image voxels and neglect the heterogeneity of physiologic models, which can work well for single-organ parametric imaging but may significantly compromise total-body parametric imaging on a scanner with a long axial field of view. In this paper, we evaluate the necessity of voxelwise compartmental modeling strategies, including time delay correction (TDC) and model selection, for total-body multiparametric imaging. Methods: Ten subjects (5 patients with metastatic cancer and 5 healthy volunteers) were scanned on a total-body PET/CT system after injection of 370 MBq of 18F-FDG. Dynamic data were acquired for 60 min. Total-body parametric imaging was performed using 2 approaches. One was the conventional method that uses a single irreversible 2-tissue-compartment model with and without TDC. The second approach selects the best kinetic model from 3 candidate models for individual voxels. The differences between the 2 approaches were evaluated for parametric imaging of microkinetic parameters and the 18F-FDG net influx rate, KiResults: TDC had a nonnegligible effect on kinetic quantification of various organs and lesions. The effect was larger in lesions with a higher blood volume. Parametric imaging of Ki with the standard 2-tissue-compartment model introduced vascular-region artifacts, which were overcome by the voxelwise model selection strategy. Conclusion: The time delay and appropriate kinetic model vary in different organs and lesions. Modeling of the time delay of the blood input function and model selection improved total-body multiparametric imaging.

来源:J Nucl Med,查看原文。版权归原作者所有。

引用

  1. Wang G, Nardo L, Parikh M, et al. Total-Body PET Multiparametric Imaging of Cancer Using a Voxelwise Strategy of Compartmental Modeling. J Nucl Med. 2021. PMID: 34795014. doi:10.2967/jnumed.121.262668

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。