清醒与睡眠运动定位在脑切除手术中的比较研究
该研究开发了睡眠运动定位范式,用于胶质瘤手术中精准检测皮质脊髓束,并与清醒运动定位患者比较。结果显示睡眠组16例、清醒组23例随访运动功能均改善或无变化,睡眠组平均切除程度88.71%高于清醒组80.62%,但差异无统计学意义(P=0.3802)。
要点
- 睡眠运动定位用于胶质瘤手术中检测皮质脊髓束安全可行
- 睡眠组平均切除程度88.71%高于清醒组80.62%,但差异无统计学意义
- 两组随访运动功能均改善或无变化
核心结论
- 在小样本系列中,使用常用运动诱发电位硬件的睡眠运动定位在切除程度和功能结局方面安全有效。
研究设计与样本
- 连续队列研究,纳入成人疑似弥漫性胶质瘤、肿瘤位于中央前回区域、接受清醒或睡眠皮质及皮质下运动定位且运动刺激阳性的患者。
主要发现
- 睡眠组16例患者末次随访(至少3个月)运动功能均改善或无变化。
- 清醒组23例患者末次随访运动功能均改善或无变化。
- 睡眠组平均(SD)切除程度为88.71%(17.56%),清醒组为80.62%(24.44%),差异无统计学意义(P=0.3802)。
- 睡眠组(n=14)刺激至皮质脊髓束距离线性回归r=-0.3759,R2=0.1413,P=0.1853,95%CI -0.4453至0.09611。
- 清醒组(n=4)刺激至皮质脊髓束距离线性回归r=0.7326,R2=0.5367,P=0.2674,95%CI -7.042至14.75。
临床怎么用
- 对于中央前回区域疑似弥漫性胶质瘤,可考虑使用睡眠运动定位辅助切除。
局限性
- 小样本患者系列,结论需更大样本验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To develop an asleep motor mapping paradigm for accurate detection of the corticospinal tract during glioma surgery and compare outcomes with awake patients undergoing glioma resection. METHODS: A consecutive cohort of adult patients undergoing craniotomy for suspected diffuse glioma with tumor in a perirolandic location who had awake or asleep cortical and subcortical motor mapping with positive areas of motor stimulation were assessed for postoperative extent of resection (EOR), permanent neurological deficit, and proximity of stimulation to diffusion tensor imaging-based corticospinal tract depiction on preoperative magnetic resonance imaging. Outcome data were compared between asleep and awake groups. RESULTS: In the asleep group, all 16 patients had improved or no change in motor function at last follow-up (minimum 3 months of follow-up). In the awake group, all 23 patients had improved function or no change at last follow-up. EOR was greater in the asleep group (mean [SD] EOR 88.71% [17.56%]) versus the awake group (mean [SD] EOR 80.62% [24.44%]), although this difference was not statistically significant (P = 0.3802). Linear regression comparing distance from stimulation to corticospinal tract in asleep (n = 14) and awake (n = 4) patients was r = -0.3759, R2 = 0.1413, P = 0.1853, and 95% confidence interval = -0.4453 to 0.09611 and r = 0.7326, R2 = 0.5367, P = 0.2674, and 95% confidence interval = -7.042 to 14.75, respectively. CONCLUSION: In this small patient series, asleep motor mapping using commonly available motor evoked potential hardware appears to be safe and efficacious in regard to EOR and functional outcomes.
引用
- Murcia D, D'Souza S, Abozeid M, et al. Investigation of Asleep versus Awake Motor Mapping in Resective Brain Surgery. World Neurosurg. 2021. PMID: 34619401. doi:10.1016/j.wneu.2021.09.119
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。