MRI影像组学鉴别低级别胶质瘤与胶质母细胞瘤瘤周区域
本研究纳入42例胶质母细胞瘤(GBM)和36例低级别胶质瘤(LGG)患者,基于1.5T MRI的T1W增强、T2W-FLAIR和弥散加权序列提取影像组学特征,使用四种机器学习分类器构建模型。采用留一法交叉验证评估,AdaBoost分类器使用全部特征时敏感度91%、特异度86%、准确率89%、AUC 0.96,表明定量分析可有效区分GBM瘤周区域与LGG。
要点
- 影像组学可区分GBM瘤周区域与LGG,视觉评估无法鉴别。
- AdaBoost分类器使用全部特征时AUC达0.96。
- 递归特征消除法AUC范围为0.87至0.92。
核心结论
- 常规MRI序列的定量分析可有效区分GBM瘤周区域与LGG,而视觉评估无法鉴别。
研究设计与样本
- 纳入42例GBM和36例LGG患者,使用1.5T MRI的T1W增强、T2W-FLAIR和弥散加权序列,手动分割T2W高信号区域,提取91个一阶和纹理特征,经滤波后获得3822个特征,采用四种机器学习分类器建模,留一法交叉验证评估性能。
主要发现
- AdaBoost分类器使用全部特征时敏感度91%、特异度86%、准确率89%、AUC 0.96。
- 递归特征消除技术AUC范围为0.87至0.92。
- F检验筛选出3个T1W增强纹理特征在超过90%的情况下被选中。
临床怎么用
- 对于视觉评估难以鉴别的GBM瘤周区域与LGG,可采用基于常规MRI的影像组学方法辅助区分。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The peritumoral region (PTR) of glioblastoma (GBM) appears as a T2W-hyperintensity and is composed of microscopic tumor and edema. Infiltrative low grade glioma (LGG) comprises tumor cells that seem similar to GBM PTR on MRI. The work here explored if a radiomics-based approach can distinguish between the two groups (tumor and edema versus tumor alone). METHODS: Patients with GBM and LGG imaged using a 1.5 T MRI were included in the study. Image data from cases of GBM PTR, and LGG were manually segmented guided by T2W hyperintensity. A set of 91 first-order and texture features were determined from each of T1W-contrast, and T2W-FLAIR, diffusion-weighted imaging sequences. Applying filtration techniques, a total of 3822 features were obtained. Different feature reduction techniques were employed, and a subsequent model was constructed using four machine learning classifiers. Leave-one-out cross-validation was used to assess classifier performance. RESULTS: The analysis included 42 GBM and 36 LGG. The best performance was obtained using AdaBoost classifier using all the features with a sensitivity, specificity, accuracy, and area of curve (AUC) of 91%, 86%, 89%, and 0.96, respectively. Amongst the feature selection techniques, the recursive feature elimination technique had the best results, with an AUC ranging from 0.87 to 0.92. Evaluation with the F-test resulted in the most consistent feature selection with 3 T1W-contrast texture features chosen in over 90% of instances. CONCLUSIONS: Quantitative analysis of conventional MRI sequences can effectively demarcate GBM PTR from LGG, which is otherwise indistinguishable on visual estimation.
引用
- Malik N, Geraghty B, Dasgupta A, et al. MRI radiomics to differentiate between low grade glioma and glioblastoma peritumoral region. J Neurooncol. 2021. PMID: 34694564. doi:10.1007/s11060-021-03866-9