弥散加权成像高信号监测恶性胶质瘤光动力治疗后急性反应与局部复发
本研究纳入2017至2020年接受手术联合光动力治疗的30例恶性胶质瘤患者,分析术后弥散加权成像信号变化与复发模式的关系。所有患者术后第1天切除腔表面出现线状短暂高信号,约30天消失且无神经功能恶化;平均随访14.3个月,19例复发,其中10例局部复发均起源于术后第1天无高信号区域。
要点
- 光动力治疗后第1天切除腔表面线状高信号为急性反应,约30天消失且无症状。
- 局部复发均发生于术后第1天无高信号区域,该征象有助于监测局部复发。
- 平均随访14.3个月,30例中19例(63%)复发,局部10例、远处1例、播散8例。
核心结论
- 恶性胶质瘤光动力治疗后的局部复发发生于术后第1天弥散加权成像无高信号的区域,该特征性表现有助于监测局部复发。
研究设计与样本
- 单中心回顾性分析,纳入2017至2020年接受光动力治疗的恶性胶质瘤患者30例(男性16例,中位年龄60.5岁),分析术后弥散加权成像信号变化与复发模式的关系。
主要发现
- 所有患者术后第1天切除腔表面出现线状高信号,约30天消失且无神经功能恶化。
- 平均光动力治疗后随访14.3个月,19例(63%)复发,其中局部10例、远处1例、播散8例。
- 全部局部复发均起源于术后第1天弥散加权成像无高信号区域。
临床怎么用
- 术后第1天弥散加权成像切除腔表面线状高信号可视为光动力治疗的预期急性反应,无需因无症状信号改变过度干预。
- 术后第1天无高信号区域应重点监测,警惕局部复发。
局限性
- 单中心小样本回顾性研究,样本量30例,随访时间有限,结果需更大规模研究验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Photodynamic therapy (PDT) subsequent to surgical tumor removal is a novel localized treatment for malignant glioma that provides effective local control. The acute response of malignant glioma to PDT can be detected as linear transient hyperintense signal on diffusion-weighted imaging (DWI) and a decline in apparent diffusion coefficient values without symptoms. However, their long-term clinical significance has not yet been examined. The aim of this study was to clarify the link between hyperintense signal on DWI as an acute response and recurrence after PDT in malignant glioma. METHODS: Thirty patients (16 men; median age, 60.5 years) underwent PDT for malignant glioma at our institution between 2017 and 2020. We analyzed the signal changes on DWI after PDT and the relationship between these findings and the recurrence pattern. RESULTS: All patients showed linear hyperintense signal on DWI at the surface of the resected cavity from day 1 after PDT. These changes disappeared in about 30 days without any neurological deterioration. During a mean post-PDT follow-up of 14.3 months, 19 patients (63%) exhibited recurrence: 10 local, 1 distant, and 8 disseminated. All of the local recurrences arose from areas that did not show hyperintense signal on DWI obtained on day 1 after PDT. CONCLUSIONS: The local recurrence in malignant glioma after PDT occurs in an area without hyperintense signal on DWI as an acute response to PDT. This characteristic finding could aid in the monitoring of local recurrence after PDT.
引用
- Fujita Y, Nagashima H, Tanaka K, et al. Hyperintense signal on diffusion-weighted imaging for monitoring the acute response and local recurrence after photodynamic therapy in malignant gliomas. J Neurooncol. 2021. PMID: 34550511. doi:10.1007/s11060-021-03845-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。