顶枕叶转移瘤术后视野缺损的避免与改善
研究纳入49例顶枕叶脑转移瘤患者,分析累及或邻近视辐射手术后半盲的改善情况。33例术前同向偏盲,其中17例(51.5%)术后视野改善,所有患者术后视野均未恶化。结论提示经合适手术路径全切肿瘤有助于保留视辐射并改善术后视野。
要点
- 顶枕叶转移瘤患者术前同向偏盲常见,术后视野可改善且不恶化。
- 视辐射常向肿瘤外侧偏移,手术宜从肿瘤内侧入路。
- 视觉改善组中绝大多数实现肿瘤全切。
核心结论
- 顶枕交界区肿瘤常使视辐射向肿瘤外侧偏移,经合适路径全切肿瘤可保留视辐射并改善术后视野。
研究设计与样本
- 本研究纳入49例顶枕叶脑转移瘤患者,术前术后评估视野、简易精神状态检查和卡氏功能状态评分。
主要发现
- 49例中33例(67.3%)术前存在同向偏盲,其中17例(51.5%)术后视野改善。
- 所有患者无论术前有无偏盲,术后视野均未恶化。
- 弥散张量成像示视辐射被肿瘤分开6例,纤维沿肿瘤外侧扩展11例。
- 视觉改善组中16/17例(94.1%)实现肿瘤全切。
临床怎么用
- 对顶枕叶转移瘤,可考虑经肿瘤内侧入路争取全切以保留视辐射并改善术后视野。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Visual field defects occasionally occur secondary to tumors in the parietal and the occipital lobes. The aim of this study was to analyze the efficacy of improvement in hemianopsia after surgery for metastatic brain tumors involving or adjacent to the optic radiation (OR). METHODS: The study included 49 patients with brain metastasis in the parietal and occipital lobes in the present study. Preoperative and postoperative neurological assessments included visual field, Mini-Mental State Examination, and Karnofsky performance scale. RESULTS: Of 49 patients, 33 (67.3%) presented with preoperative homonymous hemianopsia. Of these 33 patients, the visual field was improved postoperatively in 17 patients (51.5%). In all patients regardless of preoperative hemianopsia, postoperative visual fields did not deteriorate. Tractography demonstrated that the OR was split by the tumor (n = 6) and fanning of fibers expanded along the lateral side of the tumor (n = 11). All tumors were removed via surgical access toward the medial side of the tumor. Gross total resection was achieved in most tumors in the group with visual improvement (n = 16/17; 94.1%). Improvement in the visual field was attributed to tumor location in the subcortical white matter, removal rate of the tumor, and higher postoperative Karnofsky performance scale score. CONCLUSIONS: The OR tended to deviate to the lateral side of the tumor in the parieto-occipital junction. The postoperative visual field improved even in cases of an occipital tumor. Based on the present study, total resection via an appropriate surgical route should be considered to preserve the OR, leading to improvement in the postoperative visual field.
引用
- Tanaka T, Takei J, Teshigawara A, et al. Avoidance and Improvement in Visual Field Defect After Surgery for Metastatic Brain Tumors in the Parietal and the Occipital Lobe. World Neurosurg. 2021. PMID: 34530147. doi:10.1016/j.wneu.2021.09.029
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。