文献速递神经重症

颅内压脉搏波形高阶谐波质心分析

Intracranial pulse pressure waveform analysis using the higher harmonics centroid.
PubMed 文献 · Acta Neurochir (Wien) · 2021-08-13

全监测期ICP均值22.3±6.9 mm Hg与高阶谐波质心(HHC)3.64±0.46显著相关(R=0.45,p=0.022);平台波期间ICP从20.9±6.0升至53.7±9.7 mm Hg(p<10-16),HHC从3.65±0.48降至3.21±0.33(p=10-5)。

要点

  • HHC与ICP均值显著相关,支持压力波形分析辅助ICP数值记录。
  • ICP平台波期间HHC显著下降,可能反映颅内高压时波形改变。
  • HHC不受零点漂移影响,可弥补ICP均值失真。

核心结论

  • HHC与ICP良好相关,支持在ICP数值记录之外应用压力波形分析。
  • ICP均值可能受零点漂移影响,但HHC不受此误差干扰。

研究设计与样本

  • 先计算全监测期HHC与ICP的相关性,再分别计算平台波ICP升高期与基线的相关性。

主要发现

  • 全监测期均值:ICP 22.3±6.9 mm Hg与HHC 3.64±0.46显著相关(R=0.45,p=0.022)。
  • ICP平台波期间:ICP从20.9±6.0升至53.7±9.7 mm Hg(p<10-16),HHC从3.65±0.48降至3.21±0.33(p=10-5)。

临床怎么用

  • 在ICP监测中可同时观察HHC变化,辅助判断颅内高压。
  • HHC下降伴ICP升高可能提示颅内高压,但需进一步研究验证预警价值。

局限性

  • HHC下降是否为颅内高压早期预警信号尚需进一步研究。
  • ICP与HHC相关的个体化断点是否具有临床意义尚不明确。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The pulse waveform of intracranial pressure (ICP) is its distinctive feature almost always present in the clinical recordings. In most cases, it changes proportionally to rising ICP, and observation of these changes may be clinically useful. We introduce the higher harmonics centroid (HHC) which can be defined as the center of mass of harmonics of the ICP pulse waveform from the 2nd to 10th, where mass corresponds to amplitudes of these harmonics. We investigate the changes in HHC during ICP monitoring, including isolated episodes of ICP plateau waves. MATERIAL AND METHODS: Recordings from 325 patients treated between 2002 and 2010 were reviewed. Twenty-six patients with ICP plateau waves were identified. In the first step, the correlation between HHC and ICP was examined for the entire monitoring period. In the second step, the above relation was calculated separately for periods of elevated ICP during plateau wave and the baseline. RESULTS: For the values averaged over the whole monitoring period, ICP (22.3 ± 6.9 mm Hg) correlates significantly (R = 0.45, p = 0.022) with HHC (3.64 ± 0.46). During the ICP plateau waves (ICP increased from 20.9 ± 6.0 to 53.7 ± 9.7 mm Hg, p < 10-16), we found a significant decrease in HHC (from 3.65 ± 0.48 to 3.21 ± 0.33, p = 10-5). CONCLUSIONS: The good correlation between HHC and ICP supports the clinical application of pressure waveform analysis in addition to the recording of ICP number only. Mean ICP may be distorted by a zero drift, but HHC remains immune to this error. Further research is required to test whether a decline in HHC with elevated ICP can be an early warning sign of intracranial hypertension, whether individual breakpoints of correlation between ICP and its centroid are of clinical importance.

来源:Acta Neurochir (Wien),查看原文。版权归原作者所有。

引用

  1. Zakrzewska AP, Placek MM, Czosnyka M, et al. Intracranial pulse pressure waveform analysis using the higher harmonics centroid. Acta Neurochir (Wien). 2021. PMID: 34387744. doi:10.1007/s00701-021-04958-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。