上眼静脉血流模式作为特发性颅内高压静脉窦狭窄与高压的标志:一例急诊横窦支架治疗暴发性特发性颅内高压
本文报告一例24岁女性暴发性特发性颅内高压患者,表现为严重头痛和进行性视力丧失,腰椎穿刺开放压力70 mm Hg,影像显示右侧横窦狭窄。行右侧横窦至乙状窦支架置入术,术前跨狭窄压力梯度12 mm Hg且双侧上眼静脉血流逆行,术后压力梯度正常化、上眼静脉血流变为双向,视力改善、视乳头水肿好转,重复腰椎穿刺开放压力21.6 mm Hg。结论认为上眼静脉逆行血流提示严重静脉窦狭窄,支架术后恢复至正常或近正常状态可能提示手术成功。
要点
- 上眼静脉逆行血流应视为严重静脉窦狭窄的指标。
- 支架术后上眼静脉血流恢复至正常或近正常可能提示手术成功。
- 暴发性特发性颅内高压需紧急处理以挽救视力。
核心结论
- 上眼静脉逆行血流应考虑为严重静脉窦狭窄的指标。
- 特发性颅内高压支架术后上眼静脉血流恢复至正常或近正常状态可能提示手术成功。
研究设计与样本
- 个案报告,回顾性总结从初诊到干预后随访的所有病历、影像和记录。
主要发现
- 24岁女性,严重头痛和进行性视力丧失数周,严重视乳头水肿,腰椎穿刺开放压力70 mm Hg。
- CT和MRI显示颅内压升高征象,CT静脉造影显示右侧横窦狭窄。
- 支架置入前右侧横窦-乙状窦交界处跨狭窄压力梯度12 mm Hg,双侧上眼静脉血流逆行。
- 支架置入后压力梯度正常化,上眼静脉血流变为双向,患者主观视力改善,视乳头水肿好转。
- 重复腰椎穿刺开放压力21.6 mm Hg。
临床怎么用
- 在暴发性特发性颅内高压患者中,可关注上眼静脉血流模式作为严重静脉窦狭窄的提示。
- 静脉窦支架置入后上眼静脉血流改善可作为手术成功的参考指标。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Fulminant idiopathic intracranial hypertension (IIH) can cause rapid vision loss. Transverse sinus stenosis is a finding commonly associated with IIH, and transverse sinus stenting has been used to rapidly reduce intracranial pressure and improve visual symptoms. Our objective was to describe a case of immediate alteration in reversed superior ophthalmic vein (SOV) flow in a fulminant IIH patient who underwent venous sinus stenting. METHODS: All charts, imaging, and notes spanning from the initial presentation to the post-intervention follow-up were reviewed and summarized for inclusion. RESULTS: A 24-year-old woman presented with several weeks of severe headaches and progressive vision loss. She was found to have severe papilledema and the opening pressure on lumbar puncture (LP) was 70 mm Hg. Computed tomography (CT) and magnetic resonance imaging demonstrated findings consistent with elevated intracranial pressure, and CT venography revealed stenosis of the right transverse sinus. She underwent an uncomplicated diagnostic cerebral angiogram, right venous sinus manometry, and right transverse to sigmoid sinus stenting procedure. Prior to deployment of the stent, a trans-stenotic pressure gradient of 12 mm Hg was observed within the right transverse-sigmoid junction, and flow through the bilateral SOVs was retrograde. Following stent placement, the pressure gradient normalized, and SOV flow was bidirectional. She subjectively reported improved vision, and there was improving papilledema. Repeat LP yielded an opening pressure of 21.6 mm Hg. CONCLUSIONS: This case demonstrates reversed SOV flow should be considered an indicator of severe venous sinus stenosis, and restoration to normal or near normal state following stenting for IIH is likely indicative of procedural success.
引用
- Mugge L, Dang D, Curry B, et al. Superior Ophthalmic Vein Flow Patterns as a Marker of Venous Sinus Stenosis and Hypertension in Idiopathic Intracranial Hypertension: A Case of Emergent Transverse Sinus Stenting as Treatment of Fulminant Idiopathic Intracranial Hypertension. World Neurosurg. 2021. PMID: 34224883. doi:10.1016/j.wneu.2021.06.126
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。