文献速递小儿神经外科与脑积水神经重症

连续视神经鞘直径测量在脑积水脑脊液分流术中的应用

Utility of Serial Optic Nerve Sheath Diameter Measurements in Patients Undergoing Cerebral Spinal Fluid Diversion Procedures for Hydrocephalus.
PubMed 文献 · World Neurosurg · 2021-07-07

这项前瞻性观察研究对51例脑积水行脑室腹腔分流或内镜下第三脑室造瘘术的患者,在术前、术后第1、3、7天及随访时行超声测量视神经鞘直径(ONSD)。结果示ONSD≥5.5 mm与颅内压升高的临床及影像特征强相关(P<0.001),术后第7天>95%患者ONSD<5.5 mm,随访时78.6%患者进一步下降,3例分流功能障碍者ONSD较术后第7天升高。

要点

  • ONSD≥5.5 mm与颅内压升高的临床及影像特征强相关(P<0.001)。
  • 术后第7天ONSD与早期手术结局相关性好,>95%患者ONSD<5.5 mm。
  • 随访时ONSD较术后第7天升高与脑脊液分流术失败相关。

核心结论

  • 脑脊液分流术后第7天ONSD测量与早期手术结局相关性好,但许多患者在12个月随访时ONSD进一步下降。
  • 随访时ONSD较术后第7天升高与脑脊液分流术失败相关。

研究设计与样本

  • 前瞻性观察研究,纳入51例因脑积水行脑室腹腔分流或内镜下第三脑室造瘘术的患者。
  • 术前、术后第1、3、7天各时间点n=51,随访时n=31(中位随访12个月)。

主要发现

  • ONSD≥5.5 mm与颅内压升高的临床及影像特征强相关(P<0.001)。
  • 平均ONSD在术后逐渐下降,术后第7天最低(P<0.001),>95%患者该时点ONSD<5.5 mm。
  • 随访时78.6%患者ONSD进一步下降。
  • 3例分流功能障碍患者ONSD均较术后第7天升高。

关键数值与推荐

  • ONSD≥5.5 mm作为与颅内压升高临床及影像特征强相关的界值(P<0.001)。
  • 术后第7天>95%患者ONSD<5.5 mm。
  • 随访时78.6%患者ONSD较术后第7天进一步下降。

临床怎么用

  • 可用连续超声测量ONSD辅助评估脑脊液分流术的功能状态。
  • 术后第7天ONSD有助于判断早期手术结局。
  • 随访中ONSD较术后第7天升高需警惕分流术失败。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Functional status of cerebrospinal fluid (CSF) diversion procedure for hydrocephalus is difficult to assess on several occasions. We report the use of serial ultrasonographic measurement of optic nerve sheath diameter (ONSD) to assess the functional status of CSF diversion procedures in patients with hydrocephalus. METHODS: In this prospective observational study, ultrasonographic ONSD measurement was performed preoperatively, on postoperative days 1, 3, and 7 (n = 51 at each time point) and at follow-up (n = 31) in patients undergoing ventriculoperitoneal shunt or endoscopic third ventriculostomy for hydrocephalus. Change in ONSD values during first week after CSF diversion procedure and at follow-up were correlated with ventriculoperitoneal shunt/ETV function. RESULTS: ONSD ≥5.5 mm strongly correlated with clinical and imaging features of raised ICP (P < 0.001). Mean ONSD progressively decreased in the postoperative period and was the lowest on postoperative day 7 (P < 0.001) with >95% of patients having ONSD <5.5 mm at that time point. At follow-up (median, 12 months; n = 31), ONSD had further reduced in 78.6% of patients. All 3 patients with shunt dysfunction had an increase in the ONSD value compared with that on postoperative day 7. CONCLUSIONS: ONSD measurement on postoperative day 7 after CSF diversion correlates well with early surgical outcome but decreases further in many patients at a follow-up of 12 months. Rise in postoperative day 7 ONSD at follow-up correlates with failure of the CSF diversion procedure.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Subramanian S, Nair S, Moorthy RK, et al. Utility of Serial Optic Nerve Sheath Diameter Measurements in Patients Undergoing Cerebral Spinal Fluid Diversion Procedures for Hydrocephalus. World Neurosurg. 2021. PMID: 34245879. doi:10.1016/j.wneu.2021.07.003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。