文献速递功能神经外科

方向性电极后内侧下丘脑脑深部电刺激治疗难治性间歇性暴怒障碍:病例系列与术中微透析

Directional Deep Brain Stimulation of the Posteromedial Hypothalamus for Refractory Intermittent Explosive Disorder: A Case Series Using a Novel Neurostimulation Device and Intraoperative Microdialysis.
PubMed 文献 · World Neurosurg · 2021-07-26

这项前瞻性病例系列纳入4例难治性间歇性暴怒障碍(rIED)患者,采用8触点方向性电极行双侧后内侧下丘脑脑深部电刺激(pHyp-DBS),随访3、6、12个月。术中刺激时γ-氨基丁酸和甘氨酸水平明显升高;末次随访攻击行为平均改善6分(Δ:50%,P=0.003),除躯体疼痛外各领域生活质量量表均有改善,未观察到与pHyp-DBS相关的不良事件。

要点

  • 方向性电极pHyp-DBS在rIED患者中显示安全且可改善攻击行为
  • 术中微透析提示GABA与甘氨酸升高可能参与其作用机制
  • 样本量小(4例),结论需更大规模研究验证

核心结论

  • 方向性电极pHyp-DBS在难治性间歇性暴怒障碍患者中安全,并可改善攻击行为与生活质量。
  • 术中刺激时后内侧下丘脑γ-氨基丁酸和甘氨酸浓度明显升高,提示其可能的作用机制。

研究设计与样本

  • 前瞻性研究,纳入确诊rIED并接受pHyp-DBS缓解症状的患者。
  • 共4例(3男),平均年龄27±2.8岁;均诊断为rIED并伴重度智力障碍。
  • 采用8触点方向性电极行双侧pHyp-DBS,术后3、6、12个月随访。

主要发现

  • 术中刺激期间γ-氨基丁酸和甘氨酸水平明显升高。
  • 末次随访攻击行为平均改善6分(Δ:50%,P=0.003)。
  • Short Form Health Survey除躯体疼痛外各领域均有重要改善。
  • 未观察到与pHyp-DBS相关的不良事件。

临床怎么用

  • 对药物难治的严重间歇性暴怒障碍,可考虑方向性电极双侧pHyp-DBS作为个体化治疗选择。
  • 术中微透析可辅助探索pHyp-DBS的神经递质机制,但尚不构成常规临床推荐。

局限性

  • 样本量仅4例,缺乏对照,结论外推受限。
  • 全部患者伴重度智力障碍及不同合并症,人群异质性大。
  • 随访最长12个月,长期疗效与安全性未知。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Intermittent explosive disorder (IED) is a psychiatric disorder characterized by recurrent outbursts of aggressive behavior. Deep brain stimulation (DBS) in the posteromedial nucleus of the hypothalamus (pHyp) is an alternative therapy for extreme cases and shows promising results. Intraoperative microdialysis can help elucidate the neurobiological mechanism of pHyp-DBS. We sought to evaluate efficacy and safety of pHyp-DBS using 8-contact directional leads in patients with refractory IED (rIED) and the accompanying changes in neurotransmitters. METHODS: This was a prospective study in which patients with a diagnosis of rIED were treated with pHyp-DBS for symptom alleviation. Bilateral pHyp-DBS was performed with 8-contact directional electrodes. Follow-up was performed at 3, 6, and 12 months after surgery. RESULTS: Four patients (3 men, mean age 27 ± 2.8 years) were included. All patients were diagnosed with rIED and severe intellectual disability. Two patients had congenital rubella, one had a co-diagnosis of infantile autism, and the fourth presented with drug-resistant epilepsy. There was a marked increase in the levels of gamma-aminobutyric acid and glycine during intraoperative stimulation. The average improvement in aggressive behavior in the last follow-up was 6 points (Δ: 50%, P = 0.003) while also documenting an important improvement of the Short Form Health Survey in all domains except bodily pain. No adverse events associated with pHyp-DBS were observed. CONCLUSIONS: This is the first study to show the safety and beneficial effect of directional lead pHyp-DBS in patients with rIED and to demonstrate the corresponding mechanism of action through increases in gamma-aminobutyric acid and glycine concentration in the pHyp.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Contreras Lopez WO, Navarro PA, Gouveia FV, et al. Directional Deep Brain Stimulation of the Posteromedial Hypothalamus for Refractory Intermittent Explosive Disorder: A Case Series Using a Novel Neurostimulation Device and Intraoperative Microdialysis. World Neurosurg. 2021. PMID: 34325026. doi:10.1016/j.wneu.2021.07.086

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。