弥散张量成像在清醒开颅术中的准确性及特异性影响因素
该回顾性研究分析了91例成人脑肿瘤患者共100次清醒开颅手术,评估术前弥散张量成像预测皮质下刺激定位的敏感性和特异性,并探讨术后早期弥散张量成像对术后功能恢复的预测价值。结果显示术前预测敏感性92.2%、特异性69.2%,术后弥散张量成像可辅助监测神经功能缺损并预判恢复潜力。
要点
- 术前弥散张量成像定位传导束敏感性92.2%、特异性69.2%,各传导束间存在差异。
- 术后功能缺损发生于41次手术(39%),仅4例(4%)持续超过3个月。
- 术后早期弥散张量成像可显示传导束损伤,辅助预判功能恢复潜力。
核心结论
- 术前弥散张量成像能非常准确地预测传导束与肿瘤的空间位置关系,但无法反映传导束的功能状态,导致各传导束特异性不一。
研究设计与样本
- 回顾性分析2014至2019年91例成人脑肿瘤患者共100次清醒开颅手术,均使用弥散张量成像神经导航并结合术中皮质下刺激。
主要发现
- 术前弥散张量成像预测的敏感性和特异性分别为92.2%和69.2%,各传导束间存在差异。
- 术后功能缺损发生于41次手术(39%),仅4例患者(4%)持续超过3个月。
- 术后弥散张量成像总体证实手术保留了传导束,并在2例患者中分别预判了完全恢复和梗死相关部分恢复。
关键数值与推荐
- 术前弥散张量成像预测敏感性92.2%、特异性69.2%。
- 术后功能缺损发生率39%(41次手术),持续超过3个月者占4%(4例)。
临床怎么用
- 术前弥散张量成像可用于规划清醒开颅手术的传导束定位,但需结合术中皮质下刺激验证功能状态。
- 术后早期弥散张量成像可作为监测神经功能缺损和预判恢复潜力的辅助工具。
局限性
- 回顾性单中心研究,术后弥散张量成像数据仅51例患者可用。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Despite evidence of correspondence with intraoperative stimulation, there remains limited data on MRI diffusion tractography (DT)'s sensitivity to predict morbidity after neurosurgical oncology treatment. Our aims were: (1) evaluate DT against subcortical stimulation mapping and performance changes during and after awake neurosurgery; (2) evaluate utility of early post-operative DT to predict recovery from post-surgical deficits. METHODS: We retrospectively reviewed our first 100 awake neurosurgery procedures using DT- neuronavigation. Intra-operative stimulation and performance outcomes were assessed to classify DT predictions for sensitivity and specificity calculations. Post-operative DT data, available in 51 patients, were inspected for tract damage. RESULTS: 91 adult brain tumor patients (mean 49.2 years, 43 women) underwent 100 awake surgeries with subcortical stimulation between 2014 and 2019. Sensitivity and specificity of pre-operative DT predictions were 92.2% and 69.2%, varying among tracts. Post-operative deficits occurred after 41 procedures (39%), but were prolonged (> 3 months) in only 4 patients (4%). Post-operative DT in general confirmed surgical preservation of tracts. Post-operative DT anticipated complete recovery in a patient with supplementary motor area syndrome, and indicated infarct-related damage to corticospinal fibers associated with delayed, partial recovery in a second patient. CONCLUSIONS: Pre-operative DT provided very accurate predictions of the spatial location of tracts in relation to a tumor. As expected, however, the presence of a tract did not inform its functional status, resulting in variable DT specificity among individual tracts. While prolonged deficits were rare, DT in the immediate post-operative period offered additional potential to monitor neurological deficits and anticipate recovery potential.
引用
- Voets NL, Pretorius P, Birch MD, et al. Diffusion tractography for awake craniotomy: accuracy and factors affecting specificity. J Neurooncol. 2021. PMID: 34196915. doi:10.1007/s11060-021-03795-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。