文献速递功能神经外科

术中微电极与术后植入电极记录β振荡在帕金森病丘脑底核脑深部电刺激中的相关性可行性研究

Correlating Beta Oscillations from Intraoperative Microelectrode and Postoperative Implanted Electrode in Patients Undergoing Subthalamic Nucleus Deep Brain Stimulation for Parkinson Disease; A Feasibility Study.
PubMed 文献 · World Neurosurg · 2021-06-16

本研究纳入10例帕金森病患者的16个丘脑底核记录,比较术中微电极与术后植入宏电极记录的β频段局部场电位。68.75%(11/16)的病例术中可获得稳定β-LFP,两者峰值频率无显著差异,但β-LFP平均百分比存在显著差异。结论认为术中β-LFP记录可行,峰值频率可作为术后β-LFP的可靠替代指标。

要点

  • 术中微电极记录β-LFP在68.75%(11/16)的丘脑底核中稳定可行。
  • 术中与术后β-LFP峰值频率无显著差异,但平均百分比有显著差异。
  • 术中β-LFP峰值频率或可辅助定位丘脑底核内β振荡最大功率位置。

核心结论

  • 术中微电极记录β-LFP尽管信噪比低且易受外部噪声影响,仍具有可行性。
  • 术中与术后β-LFP峰值频率无显著差异,支持术中β-LFP作为术后β-LFP的可靠替代指标。

研究设计与样本

  • 纳入10例接受丘脑底核脑深部电刺激手术的帕金森病患者,共16个丘脑底核记录。
  • 术中微电极信号经放大并不同滤波,同时显示单单位神经元活动和LFP。
  • 术后从植入宏电极记录LFP,比较两种条件下β振荡的功率谱密度和峰值频率。

主要发现

  • 68.75%(11/16)的病例术中可观察到稳定的β-LFP。
  • 术中与术后β-LFP峰值频率无显著差异。
  • 术中与术后β-LFP平均百分比存在显著差异。

临床怎么用

  • 术中β-LFP峰值频率可作为术后β-LFP的可靠替代指标。
  • 术中β-LFP记录可提供信息以估计丘脑底核内β振荡最大功率的位置。

局限性

  • 术中微电极记录信噪比低,且易受外部来源噪声影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: We sought to investigate the feasibility of intraoperative local field potential (LFP) recording from the microelectrode during deep brain stimulation surgery for patients with Parkinson disease. METHODS: Sixteen subthalamic nucleus recordings from 10 Parkinson disease patients who underwent deep brain stimulation surgery were included in this study. Signals from microelectrodes were amplified and differently filtered to display real-time single-unit neuronal activity and LFP simultaneously during surgery. LFP recordings were also recorded postoperatively from the implanted macroelectrodes and, power spectral density and peak frequency of beta oscillation of LFP (beta LFP) between 2 conditions were compared. RESULTS: Stable intraoperative beta LFP were observed in 68.75% (11 of 16) cases. There was no significant difference of peak frequency between intraoperative and postoperative beta-LFP but significant difference of mean percentage of beta LFP was noted between 2 conditions. CONCLUSIONS: Despite low signal-to-noise ratio and susceptibility to noises from external sources, this study shows that intraoperative recording of beta LFP using microelectrode is feasible. And, given that no significant difference in peak frequency of beta LFP between intraoperative and postoperative LFP was found, we suggest that not only intraoperative beta LFP can be used as a reliable surrogate for postoperative beta LFP, but it can also provide us an information for estimating the location with maximal power of beta oscillation within the subthalamic nucleus.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Roh H, Kim JH, Koh SB, et al. Correlating Beta Oscillations from Intraoperative Microelectrode and Postoperative Implanted Electrode in Patients Undergoing Subthalamic Nucleus Deep Brain Stimulation for Parkinson Disease; A Feasibility Study. World Neurosurg. 2021. PMID: 34144163. doi:10.1016/j.wneu.2021.05.136

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。