新血流动力学参数预测未破裂脑动脉瘤薄壁区域:计算流体力学分析
研究回顾性分析25个未破裂动脉瘤,通过计算流体力学将彩色图与术中显微照片匹配,定义动脉瘤壁红色区域为薄壁区域(TIWR)。结果显示低振荡剪切指数(OSI)匹配率85.2%,OSI是TIWR的显著独立预测因素(OR 18.30,95%CI 3.2800-102.00,P<0.001),低OSI与TIWR强对应。
要点
- 低OSI与未破裂动脉瘤薄壁区域强对应,匹配率85.2%。
- OSI是TIWR的独立预测因素,OR 18.30,P<0.001。
- OSI预测效能(AUC 0.881)优于TAWSS(AUC 0.798)。
核心结论
- OSI可能是未破裂颅内动脉瘤薄壁区域的独特预测指标,低OSI与TIWR强对应。
研究设计与样本
- 回顾性分析25个未破裂动脉瘤,调整计算流体力学彩色图位置与方向以匹配术中显微照片。
主要发现
- 27个TIWR中,23个对应低OSI区域(匹配率85.2%),10个对应高TAWSS(37.0%),14个对应高PS(51.9%)。
- ROC曲线分析显示OSI预测效能最高(AUC 0.881),其次为TAWSS(AUC 0.798)。
- 多因素分析显示OSI是TIWR的显著独立预测因素(OR 18.30,95%CI 3.2800-102.00,P<0.001)。
关键数值与推荐
- TIWR定义为动脉瘤壁红色区域;彩色图上对应TIWR的大部分区域为OSI低(下四分位范围)、TAWSS高或PS高(上四分位范围)时定义为匹配区域。
- 匹配率按匹配区域数除以TIWR总数计算。
临床怎么用
- 术前计算流体力学分析中低OSI区域可能提示薄壁区域,有助于评估手术操作破裂风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The thin-walled regions (TIWRs) of intracranial aneurysms have a high risk of rupture during surgical manipulation. They have been reported to be predicted by wall shear stress and pressure (PS) based on computational fluid dynamics analysis, although this remains controversial. In this study, we investigated whether the oscillatory shear index (OSI) can predict TIWRs. METHODS: Twenty-five unruptured aneurysms were retrospectively analyzed; the position and orientation of the computational fluid dynamics color maps were adjusted to match the intraoperative micrographs. The red area on the aneurysm wall was defined as TIWR, and if most of the regions on the color map corresponding to TIWR were OSI low (lower quartile range), time-averaged wall shear stress (TAWSS) high, or PS high (upper quartile range), each region was defined as a matched region and divided by the total number of TIWRs to calculate the match rate. In addition, the mean values of OSI, TAWSS, and PS corresponding to TIWRs were quantitatively compared with those in adjacent thick-walled regions. RESULTS: Among 27 TIWRs of 25 aneurysms, 23, 10, and 14 regions had low OSI, high TAWSS, and high PS regions (match rate: 85.2%, 37.0%, and 51.9%), respectively. Receiver operating characteristic curve analysis demonstrated that OSI was the most effective hemodynamic parameter (area under the curve, 0.881), followed by TAWSS (0.798). Multivariate analysis showed that OSI was a significant independent predictor of TIWRs (odds ratio, 18.30 [95% CI, 3.2800-102.00], P < 0.001). CONCLUSIONS: OSI may be a unique predictor for TIWRs. Low OSI strongly corresponds with TIWRs of intracranial aneurysms.
引用
- Kimura H, Osaki S, Hayashi K, et al. Newly Identified Hemodynamic Parameter to Predict Thin-Walled Regions of Unruptured Cerebral Aneurysms Using Computational Fluid Dynamics Analysis. World Neurosurg. 2021. PMID: 34087458. doi:10.1016/j.wneu.2021.05.107
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。