颅骨修补材料与并发症关系:系统综述、网络荟萃分析与荟萃回归
该系统综述与网络荟萃分析检索1990年1月1日至2021年2月14日PubMed/MEDLINE、Google Scholar、EMBASE、Scopus及Cochrane Library数据库,纳入31篇全文,评估不同颅骨修补材料与感染、植入物外露及翻修手术的关系。结果显示PEEK翻修风险最低,但作者认为仍需进一步研究确定最佳材料。
要点
- PEEK翻修率8/157(5%;95%CI 0-11),低于自体骨、hPMMA、Ti和pPMMA。
- 总体翻修316/2032(14%;95%CI 11-17),感染463/4667(8%;95%CI 6-11)。
- 植入物外露120/1651(6%;95%CI 4-9),材料选择仍需个体化权衡。
核心结论
- PEEK似乎具有最低的颅骨修补翻修风险,但需进一步研究确定最佳材料。
研究设计与样本
- 系统综述、网络荟萃分析与荟萃回归,检索1990年1月1日至2021年2月14日五个数据库,筛查3620篇摘要,纳入31篇全文。
主要发现
- 翻修手术在18项研究中报告,发生316/2032例(14%;95%CI 11-17)。
- PEEK翻修率8/157(5%;95%CI 0-11),5项研究,优于自体骨(RR 0.20;95%CI 0.07-0.57)、hPMMA(RR 0.20;95%CI 0.07-0.60)、Ti(RR 0.39;95%CI 0.17-0.92)和pPMMA(RR 0.14;95%CI 0.04-0.51)。
- 自体骨翻修131/684(19%;95%CI 13-25;10项研究),hPMMA 61/317(18%;95%CI 9-28;7项研究),Ti 84/599(13%;95%CI 7-19;11项研究),pPMMA 7/59(9%;95%CI 1-23;3项研究),HA 25/216(12%;95%CI 4-24;4项研究)。
- 感染发生463/4667(8%;95%CI 6-11),植入物外露120/1651(6%;95%CI 4-9)。
关键数值与推荐
- PEEK与自体骨比较RR 0.20(95%CI 0.07-0.57),与hPMMA比较RR 0.20(95%CI 0.07-0.60),与Ti比较RR 0.39(95%CI 0.17-0.92),与pPMMA比较RR 0.14(95%CI 0.04-0.51)。
临床怎么用
- 颅骨修补选材时可参考PEEK较低翻修风险,但需结合缺损情况与个体因素综合决策。
局限性
- 作者指出仍需进一步研究确定最佳材料,原文未报告其他具体局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Cranioplasty is a ubiquitous neurosurgical procedure consisting of reconstruction of a pre-existing calvarial defect. Many materials are available, including polymethylmethacrylate in hand-moulded (hPMMA) and prefabricated (pPMMA) form, hydroxyapatite (HA), polyetheretherketone (PEEK) and titanium (Ti). OBJECTIVE: To perform a network meta-analysis (NMA) to assess the relationship between materials and complications of cranioplasty. METHODS: PubMed/MEDLINE, Google Scholar, EMBASE, Scopus, and The Cochrane Library were searched from January 1, 1990 to February 14, 2021. Studies detailing rates of any of infections, implant exposure, or revision surgery were included. A frequentist NMA was performed for each complication. Risk ratios (RRs) with 95% CIs were calculated for each material pair. RESULTS: A total of 3620 abstracts were screened and 31 full papers were included. Surgical revision was reported in 18 studies and occurred in 316/2032 cases (14%; 95% CI 11-17). PEEK had the lowest risk of re-operation with a rate of 8/157 (5%; 95% CI 0-11) in 5 studies, superior to autografts (RR 0.20; 95% CI 0.07-0.57), hPMMA (RR 0.20; 95% CI 0.07-0.60), Ti (RR 0.39; 95% CI 0.17-0.92), and pPMMA (RR 0.14; 95% CI 0.04-0.51). Revision rate was 131/684 (19%; 95% CI 13-25; 10 studies) in autografts, 61/317 (18%; 95%CI 9-28; 7 studies) in hPMMA, 84/599 (13%; 95% CI 7-19; 11 studies) in Ti, 7/59 (9%; 95% CI 1-23; 3 studies) in pPMMA, and 25/216 (12%; 95% CI 4-24; 4 studies) in HA. Infection occurred in 463/4667 (8%; 95% CI 6-11) and implant exposure in 120/1651 (6%; 95% CI 4-9). CONCLUSION: PEEK appears to have the lowest risk of cranioplasty revision, but further research is required to determine the optimal material.