文献速递神经肿瘤神经重症

磁共振波谱与PET-CT鉴别脑转移瘤复发与放射性坏死的可靠性

Reliability of Magnetic Resonance Spectroscopy and Positron Emission Tomography Computed Tomography in Differentiating Metastatic Brain Tumor Recurrence from Radiation Necrosis.
PubMed 文献 · World Neurosurg · 2021-05-27

该回顾性研究纳入242例曾接受全脑放疗或立体定向放射外科的脑转移瘤患者,筛选出25例需鉴别肿瘤复发与放射性坏死的病例,其中19例接受磁共振波谱(MRS)、13例接受PET-CT评估。MRS灵敏度100%、特异度50%、准确率81.8%;PET-CT灵敏度36.4%、特异度66.7%、准确率42.9%。结论认为MRS准确率优于PET-CT且阴性预测值高,更适用于鉴别复发与放射性坏死,并建议结合影像时症状辅助临床决策。

要点

  • MRS鉴别复发与放射性坏死的准确率为81.8%,优于PET-CT的42.9%。
  • MRS灵敏度达100%、特异度50%,阴性预测值高,适合排除复发。
  • PET-CT灵敏度仅36.4%、特异度66.7%,鉴别能力有限。

核心结论

  • MRS准确率优于PET-CT且阴性预测值高,更适用于鉴别肿瘤复发与放射性坏死。

研究设计与样本

  • 回顾性研究,从242例既往接受全脑放疗或立体定向放射外科的患者中筛选出25例需鉴别肿瘤复发与放射性坏死的病例。
  • 25例中19例接受MRS评估、13例接受PET-CT评估,依据影像判读、临床病程并结合手术病理或非手术治疗反应分为真阳性、假阳性、假阴性、真阴性组。

主要发现

  • MRS灵敏度100%、特异度50%、准确率81.8%。
  • PET-CT灵敏度36.4%、特异度66.7%、准确率42.9%。

临床怎么用

  • 在需鉴别脑转移瘤复发与放射性坏死时,可优先考虑MRS,其高阴性预测值有助于排除复发。
  • 影像判读时应与患者症状相关联以辅助临床决策。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Clinical and/or neuroimaging changes after whole-brain radiation therapy (WBRT) or stereotactic radiosurgery (SRS) for metastatic brain tumor(s) present the clinical dilemma of differentiating tumor recurrence from radiation necrosis. Several imaging modalities attempt to answer this clinical question, including magnetic resonance spectroscopy (MRS) and positron emission tomography (PET) computed tomography (CT). We evaluated our experience regarding the ability of MRS and PET CT to differentiate tumor recurrence from radiation necrosis in patients who have received WBRT or SRS. METHODS: We retrospectively reviewed records of 242 patients with previous WBRT or SRS to identify those who had MRS and/or PET CT to differentiate tumor recurrence from radiation necrosis. Patients were sorted into true-positive, false-positive, false-negative, and true-negative groups on the basis of imaging interpretation and clinical course combined with surgical pathology results or reaction to nonsurgical treatments including SRS, dexamethasone, or observation. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were then calculated. RESULTS: Of 25 patients presenting such diagnostic questions, 19 were evaluated with MRS and 13 with PET CT. MRS sensitivity was 100%, specificity was 50%, and accuracy was 81.8%, whereas PET CT sensitivity was 36.4%, specificity was 66.7%, and accuracy was 42.9%. CONCLUSIONS: MRS has better accuracy than PET CT and a high negative predictive value, therefore making it more useful in distinguishing recurrent tumor from radiation necrosis. We encourage correlation with symptoms at imaging to aid in clinical decision making.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Travers S, Joshi K, Miller DC, et al. Reliability of Magnetic Resonance Spectroscopy and Positron Emission Tomography Computed Tomography in Differentiating Metastatic Brain Tumor Recurrence from Radiation Necrosis. World Neurosurg. 2021. PMID: 34052453. doi:10.1016/j.wneu.2021.05.064

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。