文献速递脑血管病外科神经重症

R2eD AVM评分外部验证:预测脑动静脉畸形破裂表现

External Validation of the R2eD AVM Score to Predict the Likelihood of Rupture Presentation of Brain Arteriovenous Malformations.
PubMed 文献 · Neurosurgery · 2021-01-01

该研究回顾性纳入2009至2019年122例脑动静脉畸形患者,对R2eD AVM评分进行首次外部验证。48例(39.3%)以破裂表现就诊,R2eD评分预测破裂的AUC为0.711,多变量模型中种族(非白人)、size<3 cm和 exclusively deep venous drainage保留,AUC为0.677。结论认为尽管受样本量限制,该评分外部效度可接受。

要点

  • R2eD AVM评分外部验证预测破裂的AUC为0.711,效度可接受。
  • 队列中39.3%患者以AVM破裂表现就诊。
  • 多变量模型仅保留非白人种族、size<3 cm和 exclusively deep venous drainage。

核心结论

  • R2eD AVM评分在外部验证中显示可接受的效度,但受样本量限制。

研究设计与样本

  • 回顾性研究,2009至2019年10年间纳入122例符合标准且R2eD评分组件完整的脑AVM患者。

主要发现

  • 48例(39.3%)以AVM破裂表现就诊,队列平均年龄45.2岁,8%为非白人。
  • 单变量分析中全部5个类别与破裂风险关联的P<.15。
  • 多变量分析中非白人种族、size<3 cm和 exclusively deep venous drainage保留在模型中,AUC为0.677。
  • R2eD AVM评分预测破裂的AUC为0.711。

关键数值与推荐

  • R2eD AVM评分预测破裂的AUC为0.711。
  • 多变量模型AUC为0.677,保留变量为非白人种族、size<3 cm和 exclusively deep venous drainage。

临床怎么用

  • R2eD AVM评分可用于辅助评估脑AVM破裂表现的可能性,但需结合样本量限制解读。

局限性

  • 样本量有限,可能影响外部验证的稳健性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The R2eD AVM scoring system has been recently proposed to predict the risk of hemorrhagic presentation of brain arteriovenous malformations (AVMs). OBJECTIVE: To perform the first external validation of this R2eD AVM score. METHODS: Over a retrospective 10-yr period from 2009 to 2019, 122 patients with brain AVMs fit the inclusion criteria. All components required to calculate the R2eD AVM score had to be available. Patient demographics and score calculations were recorded, as well as the circumstances of their presentation. Multivariable analysis was performed to assess predictors of rupture in the study cohort. Next, area under the receiver operating characteristics and linear-by-linear association were employed to assess the effectiveness of the models. RESULTS: The mean age of the entire cohort was 45.2 yr, and 8% of patients were nonwhite. A total of 48 (39.3%) patients presented with AVM rupture. In univariable analysis, all 5 categories demonstrated P < .15 association with rupture risk. In multivariable analysis, race (nonwhite), size <3 cm, and exclusive deep venous drainage remained in the model with an area under the curve (AUC) of 0.677. The utilization of the R2eD AVM score yielded an AUC of 0.711. CONCLUSION: Even though mitigated by sample size, this study demonstrated acceptable external validity of the R2eD AVM score.

来源:Neurosurgery,查看原文。版权归原作者所有。

引用

  1. Bird WA, Hendrix P, Bohan C, et al. External Validation of the R2eD AVM Score to Predict the Likelihood of Rupture Presentation of Brain Arteriovenous Malformations. Neurosurgery. 2021. PMID: 33957673. doi:10.1093/neuros/nyab108

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。