IDH野生型胶质母细胞瘤瘤周区体素定量映射:区分肿瘤浸润与水肿
本研究利用低级别胶质瘤(肿瘤标记)和脑转移瘤瘤周区(水肿标记)的影像组学特征构建支持向量机分类器,在1.5T MRI的T1、T2和ADC图上提取270个特征,训练集准确率0.92、测试集0.79;将该模型应用于10例IDH野生型胶质母细胞瘤瘤周区,生成浸润与水肿的概率图,10例中9例肿瘤样信号体素比例在影像学复发区更高,7例AUC>0.50,全部体素浸润信号预测复发的AUC为0.61。
要点
- 影像组学模型可区分胶质母细胞瘤瘤周区的微观肿瘤浸润与血管源性水肿。
- 肿瘤样信号体素比例在影像学复发区更高,与未来复发区域相关。
- 全部体素浸润信号预测复发的AUC为0.61,区分能力有限。
核心结论
- 影像组学特征可在胶质母细胞瘤瘤周区区分微观肿瘤与水肿,并与未来复发区域相关。
研究设计与样本
- 模型训练使用约50%体素(下采样至10%),其余体素用于验证。
主要发现
- 影像组学模型在训练集和测试集中区分低级别胶质瘤与脑转移瘤的准确率分别为0.92和0.79。
- 在10例胶质母细胞瘤患者中,9例的肿瘤样信号体素比例在影像学复发区更高。
- 7例患者的AUC>0.50,确认正相关;全部体素浸润信号预测复发的AUC为0.61。
临床怎么用
- 可利用影像组学概率图辅助识别胶质母细胞瘤瘤周区中可能为肿瘤浸润而非单纯水肿的区域。
- 肿瘤样信号较高的区域可能提示未来复发位置,有助于靶区勾画或随访监测。
局限性
- 样本量小(10例胶质母细胞瘤),模型外推需更大样本验证。
- 全部体素浸润信号预测复发的AUC仅0.61,区分能力有限。
- 模型基于低级别胶质瘤和脑转移瘤瘤周区作为替代标记构建,非直接病理验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: The peritumoral region (PTR) in glioblastoma (GBM) represents a combination of infiltrative tumor and vasogenic edema, which are indistinguishable on magnetic resonance imaging (MRI). We developed a radiomic signature by using imaging data from low grade glioma (LGG) (marker of tumor) and PTR of brain metastasis (BM) (marker of edema) and applied it on the GBM PTR to generate probabilistic maps. METHODS: 270 features were extracted from T1-weighted, T2-weighted, and apparent diffusion coefficient maps in over 3.5 million voxels of LGG (36 segments) and BM (45 segments) scanned in a 1.5T MRI. A support vector machine classifier was used to develop the radiomics model from approximately 50% voxels (downsampled to 10%) and validated with the remaining. The model was applied to over 575,000 voxels of the PTR of 10 patients with GBM to generate a quantitative map using Platt scaling (infiltrative tumor vs. edema). RESULTS: The radiomics model had an accuracy of 0.92 and 0.79 in the training and test set, respectively (LGG vs. BM). When extrapolated on the GBM PTR, 9 of 10 patients had a higher percentage of voxels with a tumor-like signature over radiological recurrence areas. In 7 of 10 patients, the areas under curves (AUC) were > 0.50 confirming a positive correlation. Including all the voxels from the GBM patients, the infiltration signature had an AUC of 0.61 to predict recurrence. CONCLUSION: A radiomic signature can demarcate areas of microscopic tumors from edema in the PTR of GBM, which correlates with areas of future recurrence.
引用
- Dasgupta A, Geraghty B, Maralani PJ, et al. Quantitative mapping of individual voxels in the peritumoral region of IDH-wildtype glioblastoma to distinguish between tumor infiltration and edema. J Neurooncol. 2021. PMID: 33905055. doi:10.1007/s11060-021-03762-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。