尼莫地平对动脉瘤性蛛网膜下腔出血机械通气患者肺功能的影响
本研究探讨尼莫地平对动脉瘤性蛛网膜下腔出血机械通气患者氧交换的影响,将数据收集期分为尼莫地平依赖期和非依赖期,比较氧合指数。线性混合模型显示尼莫地平依赖期氧合指数较低,尤其在肺损伤或下呼吸道感染患者中下降更明显。结论提示合并肺损伤或下呼吸道感染时尼莫地平可能加重肺功能。
要点
- 尼莫地平依赖期氧合指数较非依赖期低2.3 kPa(95% CI 1.0-3.5,P<0.001)。
- 合并肺损伤时尼莫地平依赖期氧合指数下降2.8 kPa(95% CI 1.2-4.3,P<0.001)。
- 合并下呼吸道感染时氧合指数下降更明显(3.4 kPa vs 2.1 kPa,P=0.011和P=0.002)。
核心结论
- 在动脉瘤性蛛网膜下腔出血机械通气患者中,尼莫地平治疗可能使肺功能恶化,尤其合并肺损伤或下呼吸道感染时。
研究设计与样本
- 研究纳入150例动脉瘤性蛛网膜下腔出血患者,其中53例接受机械通气,29例可比较尼莫地平依赖期与非依赖期的氧合指数。
主要发现
- 尼莫地平依赖期氧合指数较非依赖期低2.3 kPa(95% CI 1.0-3.5 kPa,P<0.001)。
- 合并肺损伤时尼莫地平依赖期氧合指数下降2.8 kPa(95% CI 1.2-4.3 kPa,P<0.001)。
- 合并下呼吸道感染时氧合指数下降3.4 kPa(95% CI 0.8-6.1 kPa,P=0.011),无下呼吸道感染时下降2.1 kPa(95% CI 0.7-3.4 kPa,P=0.002)。
关键数值与推荐
- 肺损伤定义为氧合指数中位数≤40 kPa(≤300 mmHg)。
临床怎么用
- 对动脉瘤性蛛网膜下腔出血机械通气患者,使用尼莫地平时应监测肺功能,尤其合并肺损伤或下呼吸道感染时。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Nimodipine is routinely administered in patients with aneurysmal subarachnoid hemorrhage (aSAH). However, the effect of nimodipine on oxygen exchange in the lungs is insufficiently explored. METHODS: The study explored nimodipine medication in artificially ventilated patients with aSAH. The data collection period was divided into nimodipine-dependent (ND) and nimodipine-independent (NID) periods. Values for arterial partial pressure of oxygen (PaO2) and fraction of inspired oxygen (FiO2) were collected and compared between the periods. Patients were divided in those with lung injury (LI), defined as median Horowitz index (PaO2/FiO2) ≤40 kPa (≤300 mmHg), and without and in those with lower respiratory tract infection (LRTI) and without. RESULTS: A total of 53 out of 150 patients were artificially ventilated, and in 29 patients, the Horowitz index could be compared between ND and NID periods. A linear mixed model showed that during ND period the Horowitz index was 2.3 kPa (95% CI, 1.0-3.5 kPa, P<0.001) lower when compared to NID period. The model suggested that in the presence of LI, ND period is associated with a decrease of the index by 2.8 kPa (95% CI, 1.2-4.3 kPa, P<0.001). The decrease was more pronounced with LRTI than without: 3.4 kPa (95% CI, 0.8-6.1 kPa) vs. 2.1 kPa (95% CI, 0.7-3.4 kPa), P=0.011 and P=0.002, respectively. CONCLUSIONS: In patients with LI or LRTI in the context of aSAH, pulmonary function may worsen with nimodipine treatment. The drop of 2 to 3 kPa of the Horowitz index in patients with no lung pathology may not outweigh the benefits of nimodipine. However, in individuals with concomitant lung injury, the effect may be clinically relevant.
引用
- Lunkiewicz J, Brandi G, Willms J, et al. The effect of nimodipine on pulmonary function in artificially ventilated patients with aneurysmal subarachnoid hemorrhage. Acta Neurochir (Wien). 2021. PMID: 33825057. doi:10.1007/s00701-021-04837-9
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。