前胼胝体角与iNPH步态障碍及跌倒风险的相关性
基线ACA与术前跌倒风险、步态及平衡障碍(Tinetti POMA)显著相关,并可区分术后Tinetti POMA改善者。基线ACA是有用的神经影像标志物,可作为CA的补充工具预测分流反应性。
要点
- 基线ACA与iNPH患者术前跌倒风险、步态及平衡障碍显著相关。
- 基线ACA可区分VP分流术后Tinetti POMA量表改善的患者。
- ACA可作为CA的补充工具用于预测iNPH分流反应性。
核心结论
- 基线ACA是有用的神经影像标志物,可区分跌倒风险,并与术后步态和平衡障碍改善显著相关。
- ACA可能成为CA的补充工具,用于预测iNPH的分流反应性。
研究设计与样本
- 前瞻性纳入2015年5月至2019年5月单中心接受分流置入的可能iNPH患者。
- 术前及术后6个月按标准临床与MRI方案评估,从3T MRI计算CA与ACA。
主要发现
- 基线ACA与术前跌倒风险、步态及平衡障碍(Tinetti POMA量表评估)显著相关。
- 基线ACA可区分术后Tinetti POMA量表改善的患者。
临床怎么用
- 对可能iNPH患者,可术前测量ACA辅助评估跌倒风险与步态平衡障碍。
- ACA可与CA联合用于预测VP分流术后步态平衡改善的可能性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: In idiopathic normal pressure hydrocephalus (iNPH), gait and balance impairment is the most frequent symptom, and it is often associated with a higher fall risk. In a prior study, the anterior callosal angle (ACA) was validated as a reliable marker to discriminate iNPH from Alzheimer's disease and healthy controls. However, the potential correlation between the ACA with clinical symptoms and functional outcomes has not been assessed. The objective of this study is to determine the utility of the ACA in predicting gait improvement after ventriculoperitoneal (VP) shunting. METHODS: Patients with probable iNPH who underwent shunt placement at a single institution were prospectively enrolled from May 2015 to May 2019. Patients were assessed preoperatively and at 6 months postoperatively following a standard clinical and MRI protocol. Callosal angle (CA) and ACA were calculated from 3 T MRI preoperatively and at 6 months postoperatively. CA and ACA were tested for correlation with clinical scores. RESULTS: Forty-seven patients with probable INPH who completed 6-month postoperative follow-up were enrolled in the study. Baseline ACA was significantly correlated with preoperative fall risk, gait, and balance impairment assessed with Tinetti POMA scale. Additionally, baseline ACA differentiated patients who experienced improvement at Tinetti POMA scale after surgery. CONCLUSIONS: The baseline ACA is a useful neuroradiological marker to differentiate patients by fall risk and has significant correlation with the improvement in gait and balance impairment following surgery. This study demonstrated that the ACA may be a complementary tool to the CA in predicting shunt responsiveness in iNPH.
引用
- Mantovani P, Giannini G, Milletti D, et al. Anterior callosal angle correlates with gait impairment and fall risk in iNPH patients. Acta Neurochir (Wien). 2021. PMID: 33438062. doi:10.1007/s00701-020-04699-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。