深度学习自动测量13851例患者侧脑室与颅腔体积
本研究利用U-Net深度学习网络对13851例头颅CT进行侧脑室和颅腔体积的自动分割与量化,并基于年龄和性别构建正常、萎缩及脑积水患者的参考表。模型与手动分割高度一致,正常扫描侧脑室体积中位数显著小于脑积水(15.7 vs. 82.0 mL,P < 0.001)。
要点
- U-Net模型可高精度自动测量侧脑室和颅腔体积。
- 正常扫描侧脑室体积中位数显著低于脑积水患者。
- 研究提供了按年龄和性别的体积参考表。
核心结论
- 深度学习可在大样本CT中自动测量侧脑室和颅腔体积,并建立正常参考值。
研究设计与样本
- 横断面研究,使用13851例头颅CT扫描,部署U-Net网络分割侧脑室和颅腔,并与手动分割验证。
主要发现
- U-Net对侧脑室和颅腔体积测量的Dice指数分别为0.878和0.983。
- 自然语言处理识别出6239例(44.7%)正常、1827例(13.1%)脑萎缩、1185例(8.5%)脑积水报告。
- 正常扫描侧脑室体积中位数为15.7 mL,脑积水为82.0 mL,差异显著(P < 0.001)。
关键数值与推荐
- 基于年龄和性别的参考表包含正常、萎缩和脑积水扫描的中位数、第25和第75百分位数。
临床怎么用
- 可用于辅助脑积水或颅面综合征的诊断和随访,并提供CT报告中的体积参考。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: No large dataset-derived standard has been established for normal or pathologic human cerebral ventricular and cranial vault volumes. Automated volumetric measurements could be used to assist in diagnosis and follow-up of hydrocephalus or craniofacial syndromes. In this work, we use deep learning algorithms to measure ventricular and cranial vault volumes in a large dataset of head computed tomography (CT) scans. METHODS: A cross-sectional dataset comprising 13,851 CT scans was used to deploy U-Net deep learning networks to segment and quantify lateral cerebral ventricular and cranial vault volumes in relation to age and sex. The models were validated against manual segmentations. Corresponding radiologic reports were annotated using a rule-based natural language processing framework to identify normal scans, cerebral atrophy, or hydrocephalus. RESULTS: U-Net models had high fidelity to manual segmentations for lateral ventricular and cranial vault volume measurements (Dice index, 0.878 and 0.983, respectively). The natural language processing identified 6239 (44.7%) normal radiologic reports, 1827 (13.1%) with cerebral atrophy, and 1185 (8.5%) with hydrocephalus. Age-based and sex-based reference tables with medians, 25th and 75th percentiles for scans classified as normal, atrophy, and hydrocephalus were constructed. The median lateral ventricular volume in normal scans was significantly smaller compared with hydrocephalus (15.7 vs. 82.0 mL; P < 0.001). CONCLUSIONS: This is the first study to measure lateral ventricular and cranial vault volumes in a large dataset, made possible with artificial intelligence. We provide a robust method to establish normal values for these volumes and a tool to report these on CT scans when evaluating for hydrocephalus.
引用
- Maragkos GA, Filippidis AS, Chilamkurthy S, et al. Automated Lateral Ventricular and Cranial Vault Volume Measurements in 13,851 Patients Using Deep Learning Algorithms. World Neurosurg. 2021. PMID: 33421645. doi:10.1016/j.wneu.2020.12.148
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。