基于质子密度MRI与齿状-红核-丘脑束交叉靶向VIM的DBS技术:2例报告
本研究探讨质子密度加权MRI与齿状-红核-丘脑束(DRTT)纤维束成像交叉靶向丘脑腹中间核(VIM)在特发性震颤(ET)DBS手术中的可行性。2例ET患者采用该直接交叉靶向技术选择DBS靶点,术中临床测试确认震颤改善,并与间接靶向共识坐标比较。结果显示计划坐标在前后和横向方向存在差异,1例间接靶向可能导致电极位置欠佳;术后3个月两例震颤评分分别改善68%和72%。
要点
- PD加权MRI联合DRTT纤维束成像可直接交叉靶向VIM,用于ET的DBS植入。
- 直接与间接靶向的计划坐标存在前后和横向差异,间接靶向可能欠佳。
- 2例患者术后3个月震颤评分分别改善68%和72%。
核心结论
- 基于PD加权成像和DRTT纤维束成像的直接交叉靶向VIM是ET患者DBS植入的可行方法。
研究设计与样本
- 技术报告类研究,纳入2例特发性震颤患者,比较直接交叉靶向与间接靶向的DBS计划坐标。
主要发现
- 直接与间接靶向VIM的计划DBS坐标在前后方向(范围0至2.3)和横向方向(范围-0.7至1)存在差异。
- 1例患者若仅采用间接靶向而不结合PD加权VIM和DRTT可视化,可能导致电极在VIM内位置欠佳。
- 术后3个月随访,2例患者震颤症状主观和Fahn-Tolosa-Marin震颤评定量表(TRS)均显著改善(病例1:68%,病例2:72%)。
临床怎么用
- 直接交叉靶向技术可补充清醒术中测试,或在睡眠病例中独立使用,以提高手术效率和信心。
局限性
- 仅基于2例患者的技术报告,样本量小。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Direct visualization of the ventral intermediate nucleus (VIM) of the thalamus on standard MRI sequences remains elusive. Therefore, deep brain stimulation (DBS) surgery for essential tremor (ET) indirectly targets the VIM using atlas-derived consensus coordinates and requires awake intraoperative testing to confirm clinical benefits. The objective of this study was to evaluate the utility of proton density (PD)-weighted MRI and tractography of the intersecting dentato-rubro-thalamic tract (DRTT) for direct "intersectional" targeting of the VIM in ET. METHODS: DBS targets were selected by identifying the VIM on PD-weighted images relative to the DRTT in 2 patients with ET. Tremor reduction was confirmed with intraoperative clinical testing. Intended target coordinates based on the direct intersectional targeting technique were compared with consensus coordinates obtained with indirect targeting. Pre- and postoperative tremor scores were assessed using the Fahn-Tolosa-Marin tremor rating scale (TRS). RESULTS: Planned DBS coordinates based on direct versus indirect targeting of the VIM differed in both the anteroposterior (range 0 to 2.3) and lateral (range -0.7 to 1) directions. For 1 patient, indirect targeting-without PD-weighted visualization of the VIM and DRTT-would have likely resulted in suboptimal electrode placement within the VIM. At the 3-month follow-up, both patients demonstrated significant improvement in tremor symptoms subjectively and according to the TRS (case 1: 68%, case 2: 72%). CONCLUSIONS: Direct intersectional targeting of the VIM using PD-weighted imaging and DRTT tractography is a feasible method for DBS placement in patients with ET. These advanced targeting techniques can supplement awake intraoperative testing or be used independently in asleep cases to improve surgical efficiency and confidence.
引用
- Morrison MA, Lee AT, Martin AJ, et al. DBS targeting for essential tremor using intersectional dentato-rubro-thalamic tractography and direct proton density visualization of the VIM: technical note on 2 cases. J Neurosurg. 2021. PMID: 33450737. doi:10.3171/2020.8.JNS201378
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。