文献速递神经肿瘤

CISS与增强T1加权VIBE评估蝶骨平台脑膜瘤视神经管侵犯的准确性与观察者间信度比较

Accuracy and Interrater Reliability of CISS Versus Contrast-Enhanced T1-Weighted VIBE for the Presence of Optic Canal Invasion in Tuberculum Sellae Meningiomas.
PubMed 文献 · World Neurosurg · 2021-01-11

本研究回顾性纳入27例(54个视神经管)行内镜下经蝶骨平台-经蝶窦切除的蝶骨平台脑膜瘤患者,由5名不知晓术中所见的神经放射科医生评估术前CISS与增强T1加权VIBE序列对视神经管侵犯的预测价值。结果显示两种序列观察者间一致性均良好(CISS 0.635;VIBE 0.643),敏感性与特异性无显著差异,均能较好预测视神经管肿瘤侵犯。

要点

  • CISS与增强T1加权VIBE预测视神经管侵犯的观察者间一致性均良好。
  • 两种序列预测视神经侵犯的敏感性均为0.643,特异性分别为0.438与0.454。
  • 以术中所见为参考标准,两种序列的读者准确性无显著差异。

核心结论

  • CISS与VIBE序列均能较好预测蝶骨平台脑膜瘤对视神经管的肿瘤侵犯。

研究设计与样本

  • 回顾性研究纳入27例(54个视神经管)行内镜下经蝶骨平台-经蝶窦切除的蝶骨平台脑膜瘤患者。
  • 5名不知晓术中所见的神经放射科医生评估术前CISS与增强T1加权VIBE序列图像。
  • 参考标准为术中观察到的视神经管大体肿瘤侵犯。

主要发现

  • 特定象限肿瘤侵犯有无的观察者间一致性良好:CISS为0.635,VIBE为0.643(差值95%CI -0.086至0.010)。
  • 视神经侵犯的平均敏感性CISS为0.643、VIBE为0.643,特异性CISS为0.438、VIBE为0.454。
  • 以术中所见为参考标准,两种序列的读者准确性无显著差异。

关键数值与推荐

  • 在4个象限及2个位置(前床突后尖与视神经支柱)评估视神经管,任一位置存在侵犯即判该象限阳性。

临床怎么用

  • 临床可选用CISS或增强T1加权VIBE序列评估蝶骨平台脑膜瘤视神经管侵犯,两者准确性相当。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The magnetic resonance imaging sequence used to assess optic canal invasion by tuberculum sella meningiomas (TSMs) has not been standardized. Both constructive interference in steady state (CISS) and contrast-enhanced T1-weighted volume-interpolated breath-hold examination (VIBE) sequences are frequently used. The aim of the present study was to compare the accuracy and interrater reliability of these sequences in predicting optic canal invasion by TSMs. METHODS: In the present retrospective study of 27 patients (54 optic canals) who had undergone endoscopic transtuberculum transplanum resection of TSMs, images from preoperative CISS and contrast-enhanced T1-weighted VIBE sequences were assessed by 5 neuroradiologists who were unaware of the operative findings. The readers evaluated the optic canal in 4 quadrants at 2 locations (the posterior tip of the anterior clinoid process and the optic strut). A quadrant was considered positive for tumor invasion if invasion was present at either of these 2 locations. The reference standard was intraoperative observation of gross optic canal invasion. RESULTS: The interrater agreement was good for the presence or absence of tumor involvement in a particular quadrant (CISS, 0.635; VIBE, 0.643; 95% confidence interval for the difference, -0.086 to 0.010). The mean sensitivity and specificity for optic nerve invasion were 0.643 and 0.438 with CISS and 0.643 and 0.454 with VIBE, respectively. No significant differences were seen between the sequences in terms of reader accuracy when the intraoperative findings were used as the reference standard. CONCLUSION: CISS and VIBE sequences both have good accuracy in predicting for optic canal tumor invasion by TMEs.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Borghei-Razavi H, Lee J, Ibrahim B, et al. Accuracy and Interrater Reliability of CISS Versus Contrast-Enhanced T1-Weighted VIBE for the Presence of Optic Canal Invasion in Tuberculum Sellae Meningiomas. World Neurosurg. 2021. PMID: 33444830. doi:10.1016/j.wneu.2021.01.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。