基于机器学习与FET-PET鉴别多发性硬化与胶质瘤
本研究评估FET-PET联合机器学习鉴别多发性硬化(MS)与胶质瘤II°-IV°的诊断价值。共41例患者(7例MS,34例胶质瘤),胶质瘤组TBR值显著更高,SVM机器学习算法将鉴别AUC从0.79提升至0.94。
要点
- FET-PET的TBR特征有助于鉴别MS与胶质瘤II°-IV°。
- SVM机器学习算法可提升分类性能,AUC达0.94。
- 亚组分析显示TBR可鉴别MS与胶质母细胞瘤及少突胶质细胞瘤。
核心结论
- FET-PET成像有助于鉴别MS与胶质瘤II°-IV°,基于SVM的机器学习方法可提升分类性能。
研究设计与样本
- 回顾性筛选因MRI新发疑似胶质瘤病灶而行FET-PET检查的患者,纳入组织学确诊的胶质瘤II°-IV°患者及后续证实为MS的患者,提取TBR特征,构建SVM机器学习算法,并以ROC曲线下面积评估模型性能。
主要发现
- 共41例患者符合标准,包括7例MS和34例胶质瘤。
- 胶质瘤组TBR值显著高于MS组(TBRmax p=0.002;TBRmean p=0.014)。
- 亚组分析中,TBR显著鉴别MS与胶质母细胞瘤(TBRmax p=0.0003;TBRmean p=0.0003)。
- 亚组分析中,TBR显著鉴别MS与少突胶质细胞瘤(TBRmax p=0.003;TBRmean p=0.01)。
- 鉴别MS与胶质瘤II°-IV°的AUC从标准TBR分析的0.79提升至SVM机器学习算法的0.94。
临床怎么用
- 对于MRI疑似胶质瘤的新发病灶,FET-PET联合SVM机器学习分析可辅助鉴别MS与胶质瘤,减少误诊。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: This study aimed to test the diagnostic significance of FET-PET imaging combined with machine learning for the differentiation between multiple sclerosis (MS) and glioma II°-IV°. METHODS: Our database was screened for patients in whom FET-PET imaging was performed for the diagnostic workup of newly diagnosed lesions evident on MRI and suggestive of glioma. Among those, we identified patients with histologically confirmed glioma II°-IV°, and those who later turned out to have MS. For each group, tumor-to-brain ratio (TBR) derived features of FET were determined. A support vector machine (SVM) based machine learning algorithm was constructed to enhance classification ability, and Receiver Operating Characteristic (ROC) analysis with area under the curve (AUC) metric served to ascertain model performance. RESULTS: A total of 41 patients met selection criteria, including seven patients with MS and 34 patients with glioma. TBR values were significantly higher in the glioma group (TBRmax glioma vs. MS: p = 0.002; TBRmean glioma vs. MS: p = 0.014). In a subgroup analysis, TBR values significantly differentiated between MS and glioblastoma (TBRmax glioblastoma vs. MS: p = 0.0003, TBRmean glioblastoma vs. MS: p = 0.0003) and between MS and oligodendroglioma (ODG) (TBRmax ODG vs. MS: p = 0.003; TBRmean ODG vs. MS: p = 0.01). The ability to differentiate between MS and glioma II°-IV° increased from 0.79 using standard TBR analysis to 0.94 using a SVM based machine learning algorithm. CONCLUSIONS: FET-PET imaging may help differentiate MS from glioma II°-IV° and SVM based machine learning approaches can enhance classification performance.
引用
- Kebir S, Rauschenbach L, Weber M, et al. Machine learning-based differentiation between multiple sclerosis and glioma WHO II°-IV° using O-(2-[18F] fluoroethyl)-L-tyrosine positron emission tomography. J Neurooncol. 2021. PMID: 33502678. doi:10.1007/s11060-021-03701-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。