Zap-X放射外科系统治疗颅内肿瘤的技术病例报告
本文报告2例女性颅内肿瘤患者(三叉神经鞘瘤和岩斜脑膜瘤)使用Zap-X机器人放射外科系统治疗,处方剂量13 Gy至50%等剂量线,随访8个月显示症状改善或稳定,肿瘤体积分别缩小31%和56%,无重大并发症。
要点
- Zap-X是近半个世纪首个专用脑立体定向放射外科平台。
- 2例患者随访8个月肿瘤体积分别缩小31%和56%。
- 仅2例短期随访,安全性和有效性结论尚属初步。
核心结论
- 基于仅2例患者和短期随访,Zap-X放射外科机器人安全性和有效性的任何结论均为初步的。
研究设计与样本
- 技术病例报告,前瞻性收集2例接受Zap-X治疗的患者数据。
主要发现
- 2例女性患者分别患三叉神经鞘瘤和岩斜脑膜瘤,肿瘤体积分别为2.60和4.02 cm3。
- 处方剂量13 Gy至50%等剂量线。
- 随访8个月时术前症状缓解或稳定,MRI显示病灶体积分别缩小31%和56%。
- 两例患者症状均改善、肿瘤体积均缩小,未观察到重大并发症。
关键数值与推荐
- 处方剂量为13 Gy至50%等剂量线。
- 肿瘤体积分别为2.60 cm3和4.02 cm3。
- 随访8个月时病灶体积缩小分别为31%和56%。
临床怎么用
- Zap-X系统可用于颅内肿瘤的立体定向放射外科治疗,但当前证据仅限于2例短期随访。
局限性
- 仅2例患者,随访时间短(8个月),无法得出安全性和有效性的确定结论。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND IMPORTANCE: The Zap-X system (Zap Surgical Systems Inc, San Carlos, California) is a radically new surgical robot designed for brain and head and neck radiosurgery. It represents the first new dedicated brain stereotactic radiosurgery platform in almost half a century optimizing the goals of safety, speed, and accuracy. The Zap-X system was used in a required Chinese National Medical Products Administration clinical study. In early January 2020, 2 patients were treated with the Zap-X robot prior to a national COVID-19 lockdown. Both were closely followed via clinical exam and magnetic resonance imaging (MRI) imaging. Prospectively collected data were used to generate this report. CLINICAL PRESENTATION: Two female patients, each harboring either a trigeminal schwannoma or petroclival meningioma, were treated with the Zap-X robot. Respective tumor volumes were 2.60 and 4.02 cm3. A radiation dose of 13 Gy was prescribed to the 50% isodose line. At 8 mo of follow-up, preoperative symptoms were either resolved or stable and MRI imaging demonstrated a 31% and 56% reduction in lesion volume, respectively. In both patients, symptoms improved, and tumor volumes decreased, whereas no major complication was observed. CONCLUSION: Given only 2 patients and short-term follow-up, any conclusions about the safety and efficacy of the Zap-X radiosurgery robot are preliminary. However, in the absence of any other published outcomes to date, this small case series may be of interest to many radiosurgical specialists.
引用
- Pan L, Qu B, Bai J, et al. The Zap-X Radiosurgical System in the Treatment of Intracranial Tumors: A Technical Case Report. Neurosurgery. 2021. PMID: 33442727. doi:10.1093/neuros/nyaa550
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。