文献速递脑血管病外科神经重症

经桡动脉远端通路导管同轴技术用于后循环介入

Distal Access Catheters for Coaxial Radial Access for Posterior Circulation Interventions.
PubMed 文献 · World Neurosurg · 2021-01-21

该回顾性研究纳入12例后循环神经介入患者,采用经桡动脉仅用远端通路导管(DAC)的同轴技术、不使用导引导管,11/12(92%)成功完成入路与手术。作者认为该技术可提供与三轴系统相当的支撑,且以更小系统在桡动脉与椎基底动脉内保持稳定,可安全有效用于多种后循环介入。

要点

  • 经桡动脉仅用DAC同轴技术在后循环介入中11/12例成功完成。
  • 该技术可提供与三轴系统相当的支撑且系统更小。
  • 适用于机械取栓、动脉瘤、AVM栓塞等多种后循环介入。

核心结论

  • 经桡动脉使用远端通路导管的同轴构造在后循环介入中可提供与三轴系统相当的支撑,且不损失稳定性。

研究设计与样本

  • 单中心回顾性研究,检索机构数据库纳入采用同轴DAC技术行后循环介入的病例,共12例。

主要发现

  • 12例中11例(92%)成功完成入路与手术。
  • 机械取栓7例,其中2例经同一入路/技术置入支架。
  • 其余包括2例动脉瘤治疗(1例血流导向装置、1例弹簧圈栓塞)、1例颈椎脊索瘤球囊闭塞试验和1例动静脉畸形栓塞。

临床怎么用

  • 后循环/椎基底动脉介入可考虑经桡动脉仅用DAC的同轴技术,以减少导管系统尺寸并保持支撑。

局限性

  • 回顾性单中心设计,样本量12例,结果需更大样本验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The neurointerventional field is moving towards transradial access (TRA). Among the favorable indications for TRA is for posterior circulation/vertebrobasilar interventions. For some neurointerventions, a triaxial system (guide catheter, distal access catheter [DAC], and microcatheter) is typically used for optimal support. We describe application of a new technique in which we forgo use of the guide catheter, using the DAC only for coaxial access via the radial approach and its potential advantages. METHODS: A retrospective review was performed of our institutional database for cases using our coaxial distal access catheter technique for posterior circulation interventions. Patient characteristics and radiographic and clinical information were reviewed. All reviews were approved by institutional review board and ethics committee, and all patient identifiers were removed. RESULTS: A total of 12 patients were found that met our criteria. Successful access and procedural completion was achieved in 11 of 12 (92%). Mechanical thrombectomy accounted for 7 cases; 2 of these patients were also stented via the same approach/technique. Other cases included 2 successful aneurysm treatments (1 flow diverter, 1 coil embolization), a balloon test occlusion for a cervical chordoma, and an arteriovenous malformation embolization. CONCLUSIONS: TRA with a distal access catheter provides support equivalent to a triaxial system with a coaxial construct in the posterior circulation. This has the advantage of using a smaller system in the radial and vertebrobasilar artery without losing stability. This technique can be used effectively and safely for a variety of posterior circulation neuroendovascular interventions.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Srinivasan VM, Cotton PC, Burkhardt JK, et al. Distal Access Catheters for Coaxial Radial Access for Posterior Circulation Interventions. World Neurosurg. 2021. PMID: 33484884. doi:10.1016/j.wneu.2021.01.048

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。