脑组织氧张力与经颅多普勒超声的关系
本研究纳入28例动脉瘤性蛛网膜下腔出血患者,同期记录脑组织氧张力(PbtO2)与经颅多普勒超声(TCDU)的Lindegaard比值(LR)。结果显示PbtO2与LR无相关性(r²=0.048;P=0.26),LR≥3对脑缺氧特异性高(95.24%)但敏感性低(42.86%;P=0.037)。
要点
- PbtO2与同期TCDU的LR无显著相关性。
- LR≥3预测脑缺氧特异性高但敏感性低。
- TCDU无血管痉挛不能排除进展性DCI。
核心结论
- TCDU对预测脑组织缺氧具有特异性,可作为无创监测工具用于预防DCI,但敏感性低。
研究设计与样本
- 单中心回顾性研究,纳入2018年8月至2019年期间28例动脉瘤性蛛网膜下腔出血患者,同期行PbtO2和TCDU监测。
主要发现
- 28例患者中7例存在脑缺氧(PbtO2<20 mm Hg)。
- PbtO2测量值与同期记录的LR无相关性(r²=0.048;P=0.26)。
- LR≥3预测脑缺氧的特异性为95.24%,敏感性为42.86%(P=0.037)。
关键数值与推荐
- 索引试验:TCDU显示血管痉挛(LR≥3)。
- 参考标准:区域缺氧(PbtO2<20 mm Hg)。
- PbtO2结果与CT血管造影作为影像学标准进行比较。
临床怎么用
- TCDU可作为无创工具辅助DCI监测,但LR<3不能排除进展性DCI的可能。
局限性
- 样本量小(28例),仅7例脑缺氧,统计效能有限。
- 单中心回顾性设计,结果需外部验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Multimodal monitoring of intracranial pressure and brain tissue oxygen tension (PbtO2) have been increasingly used to detect delayed cerebral ischemia (DCI) after subarachnoid hemorrhage. At our center, patients who cannot be easily assessed clinically will undergo intracranial pressure and PbtO2 monitoring via a NEUROVENT-PTO bolt. We aimed to determine whether the Lindegaard ratios (LRs) computed from transcranial Doppler ultrasonography (TCDU) would correlate with, or can predict, the simultaneously recorded PbtO2 value. METHODS: Patients with aneurysmal subarachnoid hemorrhage, PbtO2 recordings from the middle cerebral artery territory, and simultaneous TCDU scans available from the ipsilateral middle cerebral artery and internal carotid artery from August 2018 to 2019 were included in the present study. The index test result was vasospasm (LR of ≥3) found on TCDU. The reference standard was the presence of regional hypoxia (PbtO2 <20 mm Hg). The PbtO2 results were compared with those from computed tomography angiography as a radiological standard. The predictive values were calculated using a contingency table and receiver operating characteristic curve. RESULTS: A total of 28 patients (6 men and 22 women; age, 59.04 ± 13.75 years) were identified with simultaneous brain tissue oxygen and TCDU recordings available. Of the 28 patients, 7 had cerebral hypoxia (PbtO2 <20 mm Hg). We found no correlation between the PbtO2 measurements and simultaneously recorded LRs (r2 = 0.048; P = 0.26). A LR of ≥3 had high specificity (95.24%) for hypoxia but relatively low sensitivity (42.86%; P = 0.037). CONCLUSION: We find TCDU to be specific for predicting cerebral hypoxia (measured via an intraparenchymal probe). Therefore, it could be a useful and noninvasive tool in the context of preventative DCI monitoring. However, given the low sensitivity, the lack of vasospasm on TCDU should not preclude the possibility of the presence of evolving DCI.
引用
- Craven CL, Sae-Huang M, Hoskote C, et al. Relationship between Brain Tissue Oxygen Tension and Transcranial Doppler Ultrasonography. World Neurosurg. 2021. PMID: 33513443. doi:10.1016/j.wneu.2021.01.070
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。