本研究为5例成人重型颅脑创伤(TBI)病例系列,同步记录双频指数(BIS)镇静深度、颅内压(ICP)与动脉血压(ABP),并推导压力反应性指数(PRx)与RAP。描述性绘图显示每例患者BIS与PRx呈抛物线关系,提示可能存在个体化「最佳」镇静深度以使脑血管反应性最完整。

要点

  • 成人TBI中镇静深度(BIS)与PRx可能呈抛物线关系。
  • 可能存在个体化最佳镇静深度以优化脑血管反应性。
  • 需进一步研究客观镇静深度对TBI脑生理的影响。

核心结论

  • 小样本病例系列提示镇静深度可能影响TBI患者脑血管反应性,并可能存在个体化最佳镇静深度。

研究设计与样本

  • 前瞻性维护数据库中的5例成人TBI病例系列,同步高频记录BIS、ICP与ABP并推导PRx与RAP。

主要发现

  • 通过误差条图可见每例患者BIS与PRx呈抛物线关系。
  • 该关系提示可能存在使脑血管反应性最完整的「最佳」镇静深度。

临床怎么用

  • 在神经重症监护中可考虑同步监测客观镇静深度(BIS)与脑血管反应性指标(PRx),探索个体化镇静策略。

局限性

  • 仅为5例病例系列,采用描述性绘图探索关系,不能确立因果或推广。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Impaired cerebrovascular reactivity appears to be linked to worse global outcome in adult traumatic brain injury (TBI). Literature suggests that current treatments administered in TBI care, in the intensive care unit (ICU), fail to greatly impact recorded cerebrovascular reactivity measures. In particular, the impact of sedation on cerebrovascular reactivity in traumatic brain injury (TBI) remains unclear in vivo. The goal of this study was to preliminarily assess the relationship between objectively measured depth of sedation and cerebrovascular reactivity in TBI. METHODS: Within, we describe a case series of 5 adult TBI patients with TBI, during which objective high-frequency physiology for sedation depth, using bispectral index (BIS), and both intracranial pressure (ICP) and arterial blood pressure (ABP) were recorded. Pressure reactivity index (PRx) and RAP (a metric of cerebral compensatory reserve) were derived. Relationships between cerebrovascular reactivity and compensatory reserve monitoring with BIS metrics were explored using descriptive plots. RESULTS: A total of 5 cases in our prospectively maintained database with high-frequency physiology for ICP, ABP, and BIS. Through error bar plotting, it can be seen that each patient displays a parabolic relationship between BIS and PRx. This suggests a potential "optimal" depth of sedation where cerebrovascular reactivity is the most intact. CONCLUSIONS: This small series highlights the potential impact of depth of sedation on cerebrovascular reactivity in TBI. It suggests that there may be an individual optimal depth of sedation, so as to optimize cerebrovascular reactivity. Further study of objective depth of sedation and its impact on cerebrovascular physiology in TBI is required.

来源:Acta Neurochir (Wien),查看原文。版权归原作者所有。

引用

  1. Froese L, Dian J, Gomez A, et al. Sedation and cerebrovascular reactivity in traumatic brain injury: another potential avenue for personalized approaches in neurocritical care? Acta Neurochir (Wien). 2021. PMID: 33404872. doi:10.1007/s00701-020-04662-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。