结合MRI影像组学与超声弹性成像定义脑膜瘤质地:机器学习分类器初步研究
本研究回顾性分析18例幕上脑膜瘤患者,以术中超声弹性成像(IOUS-E)测得的平均组织弹性阈值120区分硬/软质地,提取术前MRI(T1增强、ADC图、T2)影像组学特征,结合多种机器学习算法构建预测模型。最佳模型(Information Gain+ReliefF+Naive Bayes)的AUC为0.961,分类准确率94%。
要点
- 以IOUS-E弹性阈值120定义脑膜瘤硬/软质地。
- 基于T1增强、ADC图、T2的影像组学特征可预测质地。
- 最佳模型AUC 0.961、准确率94%,但样本仅18例。
核心结论
- 基于术前MRI影像组学特征可高精度预测脑膜瘤质地,最佳模型AUC为0.961、分类准确率94%。
研究设计与样本
- 回顾性分析2018年3月至2020年7月手术的幕上脑膜瘤,纳入有IOUS-E研究者,共18例。
- 以IOUS-E弹性图半定量分析定义质地,提取术前MRI影像组学特征。
- 采用特征选择过滤器联合多种机器学习算法建模,并进行分层5折交叉验证。
- 以AUC和分类准确率评估模型。
主要发现
- 按平均组织弹性阈值120将脑膜瘤分为硬或软。
- 最佳影像组学特征来自T1加权增强、表观扩散系数图(ADC)和T2加权图像。
- Information Gain与ReliefF过滤器联合Naive Bayes算法所得模型AUC为0.961、分类准确率94%。
关键数值与推荐
- 脑膜瘤质地分类阈值:平均组织弹性120。
- 最佳模型AUC 0.961,分类准确率94%。
临床怎么用
- 可尝试用术前MRI影像组学辅助判断脑膜瘤质地,为手术规划与切除范围评估提供参考。
局限性
- 样本量仅18例,属初步研究。
- 为回顾性分析。
- 质地参考标准为术中超声弹性成像。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The consistency of meningioma is a factor that may influence surgical planning and the extent of resection. The aim of our study is to develop a predictive model of tumor consistency using the radiomic features of preoperative magnetic resonance imaging and the tumor elasticity measured by intraoperative ultrasound elastography (IOUS-E) as a reference parameter. METHODS: A retrospective analysis was performed on supratentorial meningiomas that were operated on between March 2018 and July 2020. Cases with IOUS-E studies were included. A semiquantitative analysis of elastograms was used to define the meningioma consistency. MRIs were preprocessed before extracting radiomic features. Predictive models were built using a combination of feature selection filters and machine learning algorithms: logistic regression, Naive Bayes, k-nearest neighbors, Random Forest, Support Vector Machine, and Neural Network. A stratified 5-fold cross-validation was performed. Then, models were evaluated using the area under the curve and classification accuracy. RESULTS: Eighteen patients were available for analysis. Meningiomas were classified as hard or soft according to a mean tissue elasticity threshold of 120. The best-ranked radiomic features were obtained from T1-weighted post-contrast, apparent diffusion coefficient map, and T2-weighted images. The combination of Information Gain and ReliefF filters with the Naive Bayes algorithm resulted in an area under the curve of 0.961 and classification accuracy of 94%. CONCLUSIONS: We have developed a high-precision classification model that is capable of predicting consistency of meningiomas based on the radiomic features in preoperative magnetic resonance imaging (T2-weighted, T1-weighted post-contrast, and apparent diffusion coefficient map).
引用
- Cepeda S, Arrese I, García-García S, et al. Meningioma Consistency Can Be Defined by Combining the Radiomic Features of Magnetic Resonance Imaging and Ultrasound Elastography. A Pilot Study Using Machine Learning Classifiers. World Neurosurg. 2020. PMID: 33259973. doi:10.1016/j.wneu.2020.11.113
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。