文献速递功能神经外科

丘脑底核DBS中纤维束刺激对帕金森病震颤控制的影响

Neuromodulation of the subthalamic nucleus in Parkinson's disease: the effect of fiber tract stimulation on tremor control.
PubMed 文献 · Acta Neurochir (Wien) · 2020-11-10

该回顾性分析纳入36例接受STN-DBS治疗的帕金森病患者,通过概率纤维追踪显示60个大脑半球的齿状核-红核-丘脑束(DRT),发现引起静息震颤改善的电极触点距DRT更近(中位1.6 mm),优于无应答者(中位2.8 mm),提示STN-DBS的震颤控制与触点至DRT距离相关。

要点

  • STN-DBS震颤改善与活性触点至DRT距离相关
  • 改善组触点距DRT中位1.6 mm,无应答组2.8 mm
  • 纤维追踪可能辅助DBS靶点选择与术后参数调整

核心结论

  • STN-DBS中帕金森病患者的震颤控制更好与活性电极触点至DRT的距离相关。

研究设计与样本

  • 回顾性分析纳入36例连续接受STN-DBS治疗致残性运动症状(含震颤)的帕金森病患者,中位年龄65.5岁。
  • 采用直接MRI靶向和术中微电极记录植入电极至STN运动区。
  • 对60个大脑半球行3-T MRI概率纤维追踪显示DRT。

主要发现

  • 12例患者仅有单侧震颤,相应12个半球被排除进一步影像分析。
  • 剩余60个半球与对侧静息震颤相关。
  • 引起静息震颤改善的活性触点(46个半球)至DRT距离中位1.6 mm(25-75百分位0.9-2.1),显著短于无应答者(14个半球,中位2.8 mm(2-4.6),p < 0.001)。

关键数值与推荐

  • 震颤严重程度采用统一帕金森病评定量表III(UPDRS III)术前及术后定期评估。
  • 活性触点位置通过术中立体定向X线及术后CT与3D治疗计划MRI/CT图像配准验证。
  • 在垂直视图切片上测定活性触点至同侧DRT tract的最短距离,并与震颤变化百分比相关。

临床怎么用

  • STN-DBS中可考虑利用纤维追踪辅助个体化靶点选择。
  • 术后程控调整刺激参数时可参考活性触点至DRT的距离。

局限性

  • 回顾性分析设计。
  • 单中心小样本(36例患者,60个半球)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Therapeutic effects of deep brain stimulation (DBS) of the subthalamic nucleus (STN) in Parkinson's disease (PD) may in parts be attributed to the stimulation of white matter near the targeted structure. The dentato-rubro-thalamic (DRT) tract supposed to improve tremor control in patients with essential tremor could be one candidate structure. The aim of this study was to investigate the effect of stimulation proximity to the DRT on tremor control in PD patients treated with STN-DBS. METHODS: For this retrospective analysis, we included 36 consecutive patients (median age 65.5 years) treated with STN-DBS for disabling motor symptoms including tremor. Stereotactic implantation of DBS electrodes into the motor area of the STN was performed using direct MRI-based targeting and intraoperative microelectrode recording. Tremor severity was assessed preoperatively and at regular intervals postoperatively (Unified Parkinson's Disease Rating Scale III). The DRT was visualized in 60 hemispheres after probabilistic fiber tracking (3-T MRI). The position of active electrode contacts was verified on intraoperative stereotactic X-rays and postoperative CT images after co-registration with 3D treatment planning MRI/CT images. We determined the shortest distance of active contacts to the ipsilateral DRT tracts on perpendicular view slices and correlated this value with tremor change percentage. RESULTS: Twelve patients had unilateral tremor only, and accordingly, 12 hemispheres were excluded from further imaging analysis. The remaining 60 hemispheres were associated with contralateral resting tremor. Active brain electrode contacts leading to resting tremor improvement (46 hemispheres) had a significantly shorter distance to the DRT (1.6 mm (0.9-2.1) [median (25th-75th percentiles)]) compared with contacts of non-responders (14 hemispheres, distance: 2.8 mm (2-4.6), p < 0.001). CONCLUSION: This retrospective analysis suggests that in STN-DBS, better tremor control in PD patients correlates with the distance of active electrode contacts to the DRT. Tractography may optimize both individually DBS targeting and postoperative adjustment of stimulation parameters.

来源:Acta Neurochir (Wien),查看原文。版权归原作者所有。

引用

  1. Abdulbaki A, Kaufmann J, Galazky I, et al. Neuromodulation of the subthalamic nucleus in Parkinson's disease: the effect of fiber tract stimulation on tremor control. Acta Neurochir (Wien). 2020. PMID: 33174115. doi:10.1007/s00701-020-04495-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。