文献速递功能神经外科

帕金森病丘脑底核深部脑刺激术中气颅:两种手术技术的比较及脑移位与靶点精度影响因素

Pneumocephalus in subthalamic deep brain stimulation for Parkinson's disease: a comparison of two different surgical techniques considering factors conditioning brain shift and target precision.
PubMed 文献 · Acta Neurochir (Wien) · 2020-11-10

该回顾性研究比较了46例帕金森病双侧丘脑底核DBS患者(92个靶点)采用标准技术(A组)与改良技术(B组)的靶点偏差与气颅体积。B组靶点偏差显著小于A组(0.64 mm对1.09 mm,p=0.0074),但气颅体积、脑体积及ION校正比例无显著差异。结论认为改良技术显著减少电极放置误差,但临床意义有限,两种策略均可接受。

要点

  • 改良技术(半坐位直接硬膜穿刺)可显著降低靶点偏差(0.64 mm对1.09 mm)。
  • 两组气颅体积与ION校正比例无显著差异,临床意义有限。
  • 气颅吸收后多数电极偏差复位,提示偏差源于脑移位。

核心结论

  • 改良DBS技术显著减少电极放置误差,但该差异无临床相关性。
  • 两组ION均校正大量轨迹(70%对50%),两种策略均可接受。

研究设计与样本

  • 回顾性研究纳入46例帕金森病双侧丘脑底核DBS患者,共92个靶点。
  • A组采用仰卧位标准钻孔、硬膜切开、纤维蛋白胶与明胶海绵封堵。
  • B组采用半坐位直接硬膜穿刺以减少脑脊液流失。

主要发现

  • A组平均气颅体积10.55 cm3,平均脑体积1116 cm3,平均靶点偏差1.09 mm,ION校正70%靶点。
  • B组平均气颅体积7.60 cm3(p=0.3048),平均脑体积1132 cm3(p=0.6526),平均靶点偏差0.64 mm(p=0.0074),ION校正50%靶点(p=0.4886)。
  • 气颅吸收后多数电极偏差复位至计划靶点,提示偏差由脑移位导致解剖结构位移所致。

关键数值与推荐

  • 靶点偏差通过术后即刻头部CT与术前MRI计划融合评估,并于术后1个月复查。
  • 记录气颅体积、脑萎缩及术中神经生理(ION)校正情况。
  • 最终电极位置始终由ION决定。

临床怎么用

  • 两种手术技术均可接受,选择可依据术者偏好与患者情况。
  • 术中神经生理校正对确保电极位置至关重要。

局限性

  • 回顾性设计,样本量有限(46例)。
  • 气颅体积与ION校正比例差异未达统计学显著性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Precise placement of electrodes in deep brain stimulation (DBS) may be influenced by brain shift caused by cerebrospinal fluid leaking or air inflow. We compared accuracy and treatment outcomes between a standard technique and one aiming at reducing brain shift. METHODS: We retrospectively reviewed 46 patients (92 targets) treated with bilateral subthalamic-DBS for Parkinson's disease. The patients were divided into two groups: group A surgery was performed in supine position with standard burr hole, dural opening, fibrin glue and gelfoam plugging. Group B patients were operated in a semi-sitting position with direct dural puncture to reduce CSF loss. We analysed target deviation on head CT performed immediately after surgery and at 1 month merged with preoperative MRI planning. We recorded pneumocephalus volume, brain atrophy and target correction by intraoperative neurophysiology (ION). RESULTS: In group A, the mean pneumocephalus volume was 10.55 cm3, mean brain volume 1116 cm3, mean target deviation 1.09 mm and ION corrected 70% of targets. In group B, mean pneumocephalus was 7.60 cm3 (p = 0.3048), mean brain volume 1132 cm3 (p = 0.6526), mean target deviation 0.64 mm (p = 0.0074) and ION corrected 50% of targets (p = 0.4886). Most leads' deviations realigned to the planned target after pneumocephalus reabsorbtion suggesting a deviation caused by displacement of anatomical structures due to brain shift. Definitive lead position was always decided with ION. CONCLUSIONS: The modified DBS technique significantly reduced errors of electrode placement, though such difference was clinically irrelevant. ION corrected a high amount of trajectories in both groups (70% vs 50%). The choice of either strategy is acceptable.

来源:Acta Neurochir (Wien),查看原文。版权归原作者所有。

引用

  1. Piacentino M, Beggio G, Rustemi O, et al. Pneumocephalus in subthalamic deep brain stimulation for Parkinson's disease: a comparison of two different surgical techniques considering factors conditioning brain shift and target precision. Acta Neurochir (Wien). 2020. PMID: 33174114. doi:10.1007/s00701-020-04635-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。