文献速递神经肿瘤脑血管病外科

超选择性伪连续动脉自旋标记在脑膜瘤中的应用:预测供血动脉及术前栓塞可行性

Superselective pseudocontinuous arterial spin labeling in patients with meningioma: utility in prediction of feeding arteries and preoperative embolization feasibility.
PubMed 文献 · J Neurosurg · 2020-11-13

结果显示ss-pCASL预测供血动脉敏感度87.1%、特异度87.2%,栓塞可行性阳性预测值85.2%、阴性预测值100%,观察者间及模态间一致性良好。

要点

  • ss-pCASL可无创预测脑膜瘤供血动脉,敏感度87.1%、特异度87.2%。
  • ss-pCASL判断术前栓塞可行性阴性预测值达100%。
  • 观察者间一致性κ=0.817,与DSA模态间一致性κ=0.688。

核心结论

  • 在脑膜瘤患者中,ss-pCASL能可靠预测供血动脉,并有助于评估术前栓塞可行性。

主要发现

  • ss-pCASL评估血供的观察者间一致性很好(κ=0.817,95%CI 0.771-0.863)。
  • ss-pCASL与DSA的模态间一致性良好(κ=0.688,95%CI 0.632-0.744)。
  • ss-pCASL描绘肿瘤血供的敏感度为87.1%,特异度为87.2%。
  • ss-pCASL判断栓塞可行性的阳性预测值为85.2%,阴性预测值为100%。

关键数值与推荐

  • 两名神经放射科医生独立将各标记血管对肿瘤血供的贡献评为无、次要或主要。
  • 两名神经放射科医生基于ss-pCASL图像判断每例患者栓塞的可行性。

临床怎么用

  • ss-pCASL无需碘对比剂或辐射暴露,尤其适用于无栓塞前景的患者。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Superselective pseudocontinuous arterial spin labeling (ss-pCASL) is an MRI technique in which individual vessels are labeled to trace their perfusion territories. In this study, the authors assessed its merit in defining feeding vessels and gauging preoperative embolization feasibility for patients with meningioma, using digital subtraction angiography (DSA) as the reference method. METHODS: Thirty-one consecutive patients with meningiomas were prospectively recruited, each undergoing DSA (and embolization, if feasible) before resection. All ss-pCASL imaging studies were performed 1 day prior to DSA. Two neuroradiologists independently reviewed ss-pCASL images, rating the contribution of each labeled vessel to tumor blood supply as none, minor, or major. Two neuroradiologists also gauged the feasibility of embolization in each patient, based on ss-pCASL images. Interobserver and intermodality agreement were determined using Cohen's kappa statistic. The diagnostic performance of ss-pCASL was assessed in terms of discerning tumor blood supply and the potential for embolization. RESULTS: Interobserver agreement in the rating of blood supply by ss-pCASL was very good (κ = 0.817, 95% CI 0.771-0.863), and intermodality agreement (consensus ss-pCASL readings vs DSA findings) was good (κ = 0.688, 95% CI 0.632-0.744). In delineating tumor blood supply, ss-pCASL showed high sensitivity (87.1%) and specificity (87.2%). The positive and negative predictive values for embolization feasibility were 85.2% and 100%, respectively. CONCLUSIONS: In patients with meningiomas, feeding vessels are reliably predicted by ss-pCASL. This noninvasive approach, involving no iodinated contrast or radiation exposure, is particularly beneficial if there are no prospects of embolization.

来源:J Neurosurg,查看原文。版权归原作者所有。

引用

  1. Yoo DH, Sohn CH, Cho YD, et al. Superselective pseudocontinuous arterial spin labeling in patients with meningioma: utility in prediction of feeding arteries and preoperative embolization feasibility. J Neurosurg. 2020. PMID: 33186908. doi:10.3171/2020.7.JNS201915

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。