文献速递神经肿瘤

术前DWI衍生的标准与移位ADC图预测颅内脑膜瘤质地

Predicting the consistency of intracranial meningiomas using apparent diffusion coefficient maps derived from preoperative diffusion-weighted imaging.
PubMed 文献 · J Neurosurg · 2020-11-13

本前瞻性队列研究纳入25例颅内脑膜瘤患者,获取76个感兴趣区,术前计算标准ADC(b=0,1000 s/mm²)与移位ADC(b=200,1500 s/mm²),并用硬度计测量对应肿瘤组织硬度。结果显示两者均与硬度负相关,联合低值预测硬肿瘤的阳性预测值为89%,联合高值预测软肿瘤为81%。

要点

  • 标准与移位ADC图均与脑膜瘤硬度呈显著负相关。
  • 联合低标准ADC和低移位ADC预测硬肿瘤的PPV为89%。
  • 联合高标准ADC和高移位ADC预测软肿瘤的PPV为81%。

核心结论

  • 术前DWI衍生的标准与移位ADC图联合使用可预测颅内脑膜瘤质地。

研究设计与样本

  • 前瞻性队列研究,纳入25例颅内脑膜瘤患者,获取76个感兴趣区,术前计算标准与移位ADC图,术中测量肿瘤组织硬度。

主要发现

  • 硬度与标准ADC呈显著负相关(ρ = -0.465,p < 0.01),与移位ADC亦呈显著负相关(ρ = -0.490,p < 0.01)。
  • 检测硬肿瘤(硬度≥20.8 kPa)的ROC曲线下面积标准ADC为0.820,移位ADC为0.847,两者无差异(p = 0.39)。
  • 联合低标准ADC和低移位ADC预测硬肿瘤的阳性预测值为89%,联合高标准ADC和高移位ADC预测软肿瘤(硬度<20.8 kPa)的阳性预测值为81%。

关键数值与推荐

  • 硬肿瘤定义为硬度≥20.8 kPa,软肿瘤定义为硬度<20.8 kPa。
  • 标准ADC采用b值0和1000 sec/mm²,移位ADC采用b值200和1500 sec/mm²。

临床怎么用

  • 术前可联合使用标准与移位ADC图评估脑膜瘤质地,辅助预测切除难度并制定手术策略。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The consistency of meningiomas is a critical factor affecting the difficulty of resection, operative complications, and operative time. The apparent diffusion coefficient (ADC) is derived from diffusion-weighted imaging (DWI) and is calculated using two optimized b values. While the results of comparisons between the standard ADC and the consistency of meningiomas vary, the shifted ADC has been reported to be strongly correlated with liver stiffness. The purpose of the present prospective cohort study was to determine whether preoperative standard and shifted ADC maps predict the consistency of intracranial meningiomas. METHODS: Standard (b values 0 and 1000 sec/mm2) and shifted (b values 200 and 1500 sec/mm2) ADC maps were calculated using preoperative DWI in patients undergoing resection of intracranial meningiomas. Regions of interest (ROIs) were placed within the tumor on standard and shifted ADC maps and registered on the navigation system. Tumor tissue located at the registered ROI was resected through craniotomy, and its stiffness was measured using a durometer. The cutoff point lying closest to the upper left corner of a receiver operating characteristic (ROC) curve was determined for the detection of tumor stiffness such that an ultrasonic aspirator or scissors was always required for resection. Each tumor tissue sample with stiffness greater than or equal to or less than this cutoff point was defined as hard or soft tumor, respectively. RESULTS: For 76 ROIs obtained from 25 patients studied, significant negative correlations were observed between stiffness and the standard ADC (ρ = -0.465, p < 0.01) and the shifted ADC (ρ = -0.490, p < 0.01). The area under the ROC curve for detecting hard tumor (stiffness ≥ 20.8 kPa) did not differ between the standard ADC (0.820) and the shifted ADC (0.847) (p = 0.39). The positive predictive value (PPV) for the combination of a low standard ADC and a low shifted ADC for detecting hard tumor was 89%. The PPV for the combination of a high standard ADC and a high shifted ADC for detecting soft tumor (stiffness < 20.8 kPa) was 81%. CONCLUSIONS: A combination of standard and shifted ADC maps derived from preoperative DWI can be used to predict the consistency of intracranial meningiomas.

来源:J Neurosurg,查看原文。版权归原作者所有。

引用

  1. Miyoshi K, Wada T, Uwano I, et al. Predicting the consistency of intracranial meningiomas using apparent diffusion coefficient maps derived from preoperative diffusion-weighted imaging. J Neurosurg. 2020. PMID: 33186907. doi:10.3171/2020.6.JNS20740

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。