文献速递神经肿瘤

5-ALA光荧光在内镜经鼻颅底手术中效用有限:多中心回顾性研究

Limited utility of 5-ALA optical fluorescence in endoscopic endonasal skull base surgery: a multicenter retrospective study.
PubMed 文献 · J Neurosurg · 2020-10-30

该多中心回顾性研究纳入28例术前接受5-ALA的内镜经鼻颅底病变患者,术中行蓝光内镜诊断。仅2例(7%)检测到肿瘤荧光,1例结节鞍脑膜瘤强荧光,1例垂体细胞瘤模糊荧光。除脑膜瘤可能例外,5-ALA荧光在多数内镜经鼻颅底手术中效用有限。

要点

  • 28例颅底病变中仅2例(7%)检测到肿瘤荧光,1例为结节鞍脑膜瘤强荧光。
  • 正常垂体腺在1/15例(7%)中可见微弱荧光,需注意假阳性可能。
  • 除脑膜瘤可能例外,5-ALA荧光在多数内镜经鼻颅底手术中效用有限。

核心结论

  • 除脑膜瘤可能例外,5-ALA荧光在多数内镜经鼻颅底手术中效用有限。

研究设计与样本

  • 多中心回顾性系列研究,纳入两个三级中心计划行前颅底病变切除并术前接受5-ALA的患者,共28例颅底病变。

主要发现

  • 28例中仅2例(7%)检测到肿瘤荧光:1例结节鞍脑膜瘤强荧光,1例垂体细胞瘤模糊荧光。
  • 1例(7%)正常垂体腺可见微弱荧光;其余病例均无荧光。
  • 肿瘤类型间比较及侵袭性、WHO分级、Ki-67与阳性荧光之间均无显著关联。

关键数值与推荐

  • 28例颅底病变包括15例垂体腺瘤(54%)、4例脑膜瘤(14%)、3例颅咽管瘤(11%)、2例Rathke裂囊肿(7%),以及浆细胞瘤、嗅神经母细胞瘤和鼻窦鳞状细胞癌各1例。
  • 6例(21%)显示侵袭性生长至硬脑膜、骨或海绵窦等周围结构。

临床怎么用

  • 内镜经鼻颅底手术中常规使用5-ALA荧光可能获益有限,脑膜瘤或可例外考虑。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Incomplete resection of skull base pathology may result in local tumor recurrence. This study investigates the utility of 5-aminolevulinic acid (5-ALA) fluorescence during endoscopic endonasal approaches (EEAs) to increase visibility of pathologic tissue. METHODS: This retrospective multicenter series comprises patients with planned resection of an anterior skull base lesion who received preoperative 5-ALA at two tertiary care centers. Diagnostic use of a blue light endoscope was performed during EEA for all cases. Demographic and tumor characteristics as well as fluorescence status, quality, and homogeneity were assessed for each skull base pathology. RESULTS: Twenty-eight skull base pathologies underwent blue-light EEA with preoperative 5-ALA, including 15 pituitary adenomas (54%), 4 meningiomas (14%), 3 craniopharyngiomas (11%), 2 Rathke's cleft cysts (7%), as well as plasmacytoma, esthesioneuroblastoma, and sinonasal squamous cell carcinoma. Of these, 6 (21%) of 28 showed invasive growth into surrounding structures such as dura, bone, or compartments of the cavernous sinus. Tumor fluorescence was detected in 2 cases (7%), with strong fluorescence in 1 tuberculum sellae meningioma and vague fluorescence in 1 pituicytoma. In all other cases fluorescence was absent. Faint fluorescence of the normal pituitary gland was seen in 1 (7%) of 15 cases. A comparison between the particular tumor entities as well as a correlation between invasiveness, WHO grade, Ki-67, and positive fluorescence did not show any significant association. CONCLUSIONS: With the possible exception of meningiomas, 5-ALA fluorescence has limited utility in the majority of endonasal skull base surgeries, although other pathology may be worth investigating.

来源:J Neurosurg,查看原文。版权归原作者所有。

引用

  1. Micko A, Rapoport BI, Youngerman BE, et al. Limited utility of 5-ALA optical fluorescence in endoscopic endonasal skull base surgery: a multicenter retrospective study. J Neurosurg. 2020. PMID: 33126212. doi:10.3171/2020.5.JNS201171

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。