文献速递神经重症

体位改变对颅内压与脉搏波幅的影响

Changes in intracranial pressure and pulse wave amplitude during postural shifts.
PubMed 文献 · Acta Neurochir (Wien) · 2020-09-04

该回顾性研究纳入29例接受标准化体位颅内压检查的受试者,比较仰卧位与直立位下平均颅内压(ICP)和脉搏波幅(PWA)的变化。结果显示ICP显著下降(Δ14.1 mmHg,p<0.01),PWA无显著变化(Δ0.4 mmHg,p=0.06),且两体位下ICP与PWA均呈线性相关(p<0.01)。结论提示体位改变时压力-容积曲线整体下移而斜率不变。

要点

  • 仰卧转直立位时ICP显著下降,PWA无显著改变
  • 两体位下ICP与PWA均呈线性相关
  • 提示压力-容积曲线下移而斜率不变

核心结论

  • 从仰卧位转为直立位时,ICP降低而PWA保持不变。
  • 这提示压力-容积曲线按静水压偏移整体下移,而曲线斜率不变。
  • 仰卧与直立位下ICP与PWA的相关性均得到验证。

研究设计与样本

  • 回顾性研究,回顾数据库中有标准化体位ICP检查的受试者。
  • 共纳入29例受试者,平均ICP与PWA分别用自动法和手动法测定。
  • 采用Student t检验比较,并检验仰卧与直立位下ICP与PWA的相关性。

主要发现

  • ICP变化Δ14.1 mmHg,p<0.01,差异显著。
  • PWA变化Δ0.4 mmHg,p=0.06,无显著变化。
  • 仰卧和直立位下ICP与PWA均呈线性相关,p<0.01。

临床怎么用

  • 体位改变时ICP下降不应简单以PWA变化推断,需直接监测ICP。
  • 解读PWA时需考虑体位因素,直立位下PWA与ICP关系仍成立。

局限性

  • 回顾性研究设计。
  • 样本量较小(29例)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Monitoring of intracranial pressure (ICP) and ICP pulse wave amplitude (PWA) is an integrated part of neurosurgery. An increase in ICP usually leads to an increase in PWA. These findings have yet to be replicated during the positional shift from supine to upright, where we only know that ICP decreases. Our main aim is to clarify whether the positional shift also results in a change in pulse wave amplitude. METHOD: Our database was retrospectively reviewed for subjects having had a standardized investigation of positional ICP. In all subjects, mean ICP and PWA were determined with both an automatic and a manual method and compared using Student's t test. Finally, ICP and PWA were tested for correlation in both in supine and upright position. RESULTS: The study included 29 subjects. A significant change in ICP (Δ14.1 mmHg, p < 0.01) and no significant change in PWA (Δ0.4 mmHg, p = 0.06) were found. Furthermore, a linear correlation between ICP and PWA was found in both supine and upright positions (p < 0.01). CONCLUSIONS: We found that during the positional shift from supine to upright, ICP is reduced while PWA remains unaffected. This indicates that the pressure-volume curve is shifted downward according to a hydrostatic pressure offset, while the slope of the curve does not change. In addition, the correlation between ICP and PWA in both supine and upright position validates the previous research on the matter.

来源:Acta Neurochir (Wien),查看原文。版权归原作者所有。

引用

  1. Norager NH, Olsen MH, Riedel CS, et al. Changes in intracranial pressure and pulse wave amplitude during postural shifts. Acta Neurochir (Wien). 2020. PMID: 32886224. doi:10.1007/s00701-020-04550-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。