脑膜瘤放射外科治疗后表观扩散系数值的长期变化
结果显示保守组ADC值保持稳定,而放射外科组平均ADC值随时间显著变化,提示ADC可能反映肿瘤生物学行为改变并作为治疗反应指标。
要点
- 保守治疗的脑膜瘤ADC值在随访期间保持稳定。
- 放射外科治疗的脑膜瘤平均ADC值随时间显著变化。
- ADC变化可能作为脑膜瘤治疗反应的指标。
核心结论
- 保守治疗的脑膜瘤ADC值在随访期间保持稳定。
- 接受放射外科治疗的脑膜瘤平均ADC值随时间显著变化,提示ADC可能反映肿瘤生物学行为改变。
- ADC变化可能作为治疗反应的指标。
研究设计与样本
- 回顾性分析51例脑膜瘤患者的MR图像。
- 基于ROI分析评估随访期间不同时间点的平均ADC值、ADC10%min和ADC90%max。
主要发现
- 两组基线ADC值相似。
- 保守组10年期间ADCmean为0.87 ± 0.05 × 10-3 mm2/s,随访期间无显著变化。
- 放射外科组4年期间ADCmean为1.02 ± 0.12 × 10-3 mm2/s,随访期间无显著变化。
- 比较保守组与放射外科组,ADCmean和ADC90%max差异有统计学意义(p < 0.0001)。
- ADC10%min在保守组与放射外科组之间差异有统计学意义(p < 0.05)。
临床怎么用
- 对于保守治疗的脑膜瘤,ADC值稳定可作为随访参考。
- 放射外科治疗后ADC值变化可能提示肿瘤生物学行为改变,可作为治疗反应指标。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: A noninvasive method to predict the progress or treatment response of meningiomas is desirable to improve the tumor management. Studies showed that apparent diffusion coefficient (ADC) pretreatment values can predict treatment response in brain tumors. The aim of this study was to analyze changes of intratumoral ADC values in patients with meningiomas undergoing conservative or radiosurgery. METHOD: MR images of 51 patients with diagnose of meningiomas were retrospectively reviewed. Twenty-five patients undergoing conservative or radiosurgery treatment, respectively, were included in the study. The follow-up data ranged between 1 and 10 years. Based on ROI analysis, the mean ADC values, ADC10%min, and ADC90%max were evaluated at different time points during follow-up. RESULTS: Baseline ADC values in between both groups were similar. The ADCmean values, ADC10%min, and ADC90%max within the different groups did not show any significant changes during the follow-up times in the untreated (ADCmean over 10 years period: 0.87 ± 0.05 × 10-3 mm2/s) and radiosurgically treated (ADCmean over 4 years period: 1.02 ± 0.12 × 10-3 mm2/s) group. However, statistically significant difference was observed when comparing the ADCmean and ADC90%max values of untreated with radiosurgically treated (p < 0.0001) meningiomas. Also, ADC10%min revealed statistically significant difference between the untreated and the radiosurgery group (p < 0.05). CONCLUSIONS: ADC values in conservatively managed meningiomas remain stable during the follow-up. However, meningiomas undergoing radiosurgery reveal significant change of the mean ADC values over time, suggesting that ADC may reflect a change in the biological behavior of the tumor. These observations might suggest the value of ADC changes as an indicator of treatment response.
引用
- Berberat J, Roelcke U, Remonda L, et al. Long-term apparent diffusion coefficient value changes in patients undergoing radiosurgical treatment of meningiomas. Acta Neurochir (Wien). 2020. PMID: 32909068. doi:10.1007/s00701-020-04567-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。