结果显示DCE-MRI可较准确区分高级别与低级别胶质瘤,其中t-Ktrans值具有较高的特异度和敏感度。

要点

  • DCE-MRI的t-Ktrans值可较准确区分高级别与低级别胶质瘤。
  • 低级别胶质瘤t-Ktrans值较低(P<0.01,敏感度89%,特异度99%)。
  • 原发性中枢神经系统淋巴瘤t-Ve值较高,但与其他肿瘤灌注参数重叠明显。

核心结论

  • DCE-MRI能较准确区分高级别与低级别胶质瘤,其中t-Ktrans值具有较高的特异度和敏感度。

主要发现

  • 低级别胶质瘤t-Ktrans值较低(P<0.01,敏感度89%,特异度99%),t-Ve值较低(P<0.01,敏感度94%,特异度100%)。
  • 原发性中枢神经系统淋巴瘤t-Ve值较高(P<0.01,敏感度100%,特异度88%),但其他灌注参数与其他肿瘤重叠明显。
  • t-Ktrans值区分低级别与高级别胶质瘤时,以0.154为截断值,曲线下面积1.000,P=0.000,特异度100%,敏感度94.1%。
  • 高级别胶质瘤与原发性中枢神经系统淋巴瘤的t-Ve值差异有统计学意义,后者t-Ve值略高,但敏感度和特异度不高。
  • 转移瘤的p-Ktrans值和p-Kep值低于高级别胶质瘤且特异度较高,但脑膜瘤与高级别胶质瘤、原发性中枢神经系统淋巴瘤及转移瘤的鉴别不准确。

临床怎么用

  • 临床可参考DCE-MRI的t-Ktrans值辅助鉴别高级别与低级别胶质瘤。
  • 对原发性中枢神经系统淋巴瘤与高级别胶质瘤的鉴别,t-Ve值差异有统计学意义但敏感度和特异度有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: We used dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) technology and its perfusion parameters to diagnose central glioma high-grade glioma (HGG), primary central nervous system glioma low-grade glioma (LGG), brain metastases, and meningioma and make differential diagnoses. METHODS: Forty-one cases of brain tumors (8 cases of LGG, 17 cases of HGG, 5 cases of "primary central nervous system lymphoma" [PCNSL], 6 cases of brain metastases, and 5 cases of meningiomas) were subjected to routine and DCE-MRI scans. The DCE-MRI quantitative parameters of the tumor parenchymal area and peripheral enema area of each tumor were measured and recorded as t-Ktrans value, t-Ve value, t-Vp value, t-Kep value and p-Ktrans value, p-Ve value, p-Vp value, and p-Kep value. RESULTS: Compared with other tumor types, LGG showed lower t-Ktrans value (P < 0.01, sensitivity = 89%, specificity = 99%) and low t-Ve value (P < 0.01, sensitivity = 94%, specificity = 100%); PCNSL showed a high t-Ve value (P < 0.01, sensitivity = 100%, specificity = 88%), but other perfusion parameters overlap more obviously with other tumors. Compared with LGG, the difference between t-Ktrans value, t-Ve value, and t-Kep value is statistically significant. Among them, t-Ktrans value distinguishes the highest sensitivity and specificity (when t-Ktrans value = when 0.154 is the cutoff value, the area under the curve is 1.000, P = 0.000, specificity = 100%, sensitivity = 94.1%); compared with PCNSL, the difference of t-Ve value between HGG and PCNSL is statistically significant, t-Ve of PCNSL. The value is slightly higher, and its specificity and sensitivity are not high. CONCLUSIONS: DCE-MRI can distinguish HGG and LGG more accurately, of which t-Ktrans value has higher specificity and sensitivity, although the difference of t-Ve value between PCNSL and HGG is statistically significant but the sensitivity and specificity are not high; the p-Ktrans value and p-Kep value of metastatic tumors are lower than HGG and have higher specificity, but meningiomas and HGG and PCNSL, meningiomas and metastases are not accurate identification.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Jin Y, Peng H, Peng J, et al. Brain Glioma Localization Diagnosis Based on Magnetic Resonance Imaging. World Neurosurg. 2020. PMID: 32992057. doi:10.1016/j.wneu.2020.09.113

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。