心脏门控颅内弹性测量:猪颅高压模型中新方法评估颅内压-容积动力学

Cardiac-gated intracranial elastance in a swine model of raised intracranial pressure: a novel method to assess intracranial pressure-volume dynamics.
PubMed 文献 · J Neurosurg · 2020-06-05

该研究在7头脑水肿猪模型中,采用心脏门控球囊泵在4个心动周期时相测量颅内弹性,发现弹性随颅内压升高而增加,且心脏门控测量变异更小;在颅内压20-25 mmHg时弹性值介于8.7-15.8 mmHg/ml,提示仅凭颅内压不能准确预测弹性。

要点

  • 心脏门控颅内弹性测量在猪模型中可行且精度更高。
  • 颅内弹性随颅内压升高而增加,收缩末期和舒张末期最一致。
  • 相同颅内压水平下弹性值可变,颅内压不能单独反映容积储备。

核心结论

  • 心脏门控测量颅内弹性可行且可能提高测量精度。
  • 弹性值在相似颅内压水平下存在差异,颅内压单独不能准确预测颅内弹性。
  • 配对颅内压-弹性测量或可作为早期预警监测辅助手段。

研究设计与样本

  • 研究采用作者先前描述的心脏门控颅内球囊泵和猪脑水肿模型。
  • 在7头猪中,于颅内压10-30 mmHg范围内,通过快速球囊充气至1 ml,在心动周期4个时相(收缩早期、收缩峰值、舒张中期、舒张末期)测量弹性。

主要发现

  • 颅内弹性随颅内压升高而逐渐增加。
  • 收缩峰值和舒张末期弹性随颅内压升高上升最一致。
  • 心脏门控弹性测量在猪个体内的变异显著低于非心脏门控测量。
  • 颅内压-弹性曲线斜率在猪个体间存在差异。
  • 颅内压20-25 mmHg时,弹性值介于8.7-15.8 mmHg/ml。

临床怎么用

  • 心脏门控颅内弹性测量或可提高评估颅内压-容积动力学的精度。
  • 配对颅内压-弹性测量可能有助于识别小容积增加即致颅内压升高的高风险患者。
  • 该方法目前仅为动物实验初步数据,临床转化需进一步验证。

局限性

  • 研究为猪脑水肿模型,样本量7头,结果外推至临床需谨慎。
  • 作者称数据为初步结果,方法学困难曾限制临床广泛应用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Previous studies have demonstrated the importance of intracranial elastance; however, methodological difficulties have limited widespread clinical use. Measuring elastance may offer potential benefit in helping to identify patients at risk for untoward intracranial pressure (ICP) elevation from small rises in intracranial volume. The authors sought to develop an easily used method that accounts for the changing ICP that occurs over a cardiac cycle and to assess this method in a large-animal model over a broad range of ICPs. METHODS: The authors used their previously described cardiac-gated intracranial balloon pump and swine model of cerebral edema. In the present experiment they measured elastance at 4 points along the cardiac cycle-early systole, peak systole, mid-diastole, and end diastole-by using rapid balloon inflation to 1 ml over an ICP range of 10-30 mm Hg. RESULTS: The authors studied 7 swine with increasing cerebral edema. Intracranial elastance rose progressively with increasing ICP. Peak-systolic and end-diastolic elastance demonstrated the most consistent rise in elastance as ICP increased. Cardiac-gated elastance measurements had markedly lower variance within swine compared with non-cardiac-gated measures. The slope of the ICP-elastance curve differed between swine. At ICP between 20 and 25 mm Hg, elastance varied between 8.7 and 15.8 mm Hg/ml, indicating that ICP alone cannot accurately predict intracranial elastance. CONCLUSIONS: Measuring intracranial elastance in a cardiac-gated manner is feasible and may offer an improved precision of measure. The authors' preliminary data suggest that because elastance values may vary at similar ICP levels, ICP alone may not necessarily best reflect the state of intracranial volume reserve capacity. Paired ICP-elastance measurements may offer benefit as an adjunct "early warning monitor" alerting to the risk of untoward ICP elevation in brain-injured patients that is induced by small increases in intracranial volume.