文献速递神经重症小儿神经外科与脑积水

脑室外引流放置地点对并发症的影响:ICU与手术室的系统综述

Does the Setting of External Ventricular Drain Placement Affect Morbidity? A Systematic Literature Review Comparing Intensive Care Unit versus Operating Room Procedures.
PubMed 文献 · World Neurosurg · 2020-05-08

该系统综述纳入9项研究,比较神经外科ICU床旁与手术室放置脑室外引流(EVD)的准确性与并发症。导管置入准确率ICU为68.29%(4研究,n=280),OR为84.25%(2研究,n=198);出血并发症ICU为18.16%(4研究,n=112),OR为17.50%(2研究,n=35);感染率ICU为7.28%(4研究,n=48),OR为8.06%(5研究,n=92)。综述认为现有文献在样本量和方法学一致性上均不足以得出明确结论。

要点

  • ICU与OR放置EVD在出血并发症和感染率上数值接近,但证据不充分。
  • OR放置的导管准确率数值较高,但仅基于2项研究,需谨慎解读。
  • 现有文献方法异质,无法形成改变实践的推荐。

核心结论

  • 比较ICU与OR放置EVD的文献在样本量和方法学一致性上均不充分,无法得出明确结论。
  • 可能存在特定患者群体更适合在ICU或OR放置EVD。

研究设计与样本

  • 遵循PRISMA指南的系统综述,检索PubMed截至2019年12月12日。
  • 初检356篇,全文分析37篇,最终纳入9项研究。
  • 研究分为仅OR组(3项,1011例)、仅ICU组(3项,325例)和OR+ICU组(3项,613例)。

主要发现

  • 导管置入准确率:ICU 68.29%(4项研究,n=280),OR 84.25%(2项研究,n=198)。
  • 医源性出血并发症:ICU 18.16%(4项研究,n=112),OR 17.50%(2项研究,n=35)。
  • 脑室造瘘相关感染率:ICU 7.28%(4项研究,n=48),OR 8.06%(5项研究,n=92)。

临床怎么用

  • 当前证据不足以推荐常规在ICU或OR放置EVD,临床决策需个体化。
  • 需统一结局指标和数据报告以合成高质量证据。

局限性

  • 纳入研究样本量有限,方法学异质,影响证据合成。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: External ventricular drain (EVD) placement can be performed at the bedside in the neurosurgical intensive care unit (ICU) or in the operating room (OR). Systematic review and meta-analysis may permit stronger recommendations to improve accuracy and complication rates. METHODS: Systematic review of PubMed was performed (inception-December 12, 2019) following PRISMA guidelines. RESULTS: Our search yielded 356 articles, of which 37 studies underwent full-text analysis. Nine studies met inclusion criteria. Studies were segregated into OR only (n = 3; 1011 patients), ICU only (n = 3; 325 patients), and OR + ICU (n = 3; 613 patients) cohorts. Studies were in addition divided by outcome measures, including catheter placement accuracy (ICU, 4 studies, n = 280 [68.29%] vs. OR, 2 studies, n = 198 [84.25%]); iatrogenic hemorrhagic complications (ICU, 4 studies, n = 112 [18.16%] vs. OR, 2 studies, n = 35 [17.50%]); and ventriculostomy-related infection rates (ICU, 4 studies, n = 48 [7.28%] vs. OR: 5 studies, n = 92 [8.06%]). CONCLUSIONS: There are likely specific patient populations who would benefit from EVD placement in the ICU versus OR setting. The literature comparing efficacy and morbidity between EVDs placed in the ICU and OR settings is overall inconclusive in both sample size and congruence of methodology. Agreement in outcome metrics and data reporting on this topic is necessary to synthesize high-quality evidence to form practice-changing recommendations for this debated topic.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Dawod G, Henkel N, Karim N, et al. Does the Setting of External Ventricular Drain Placement Affect Morbidity? A Systematic Literature Review Comparing Intensive Care Unit versus Operating Room Procedures. World Neurosurg. 2020. PMID: 32389865. doi:10.1016/j.wneu.2020.04.215

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。