利用OsiriX软件预测理想脑室徒手穿刺轨迹及枕部形态变异的作用
结果显示理想轨迹的枕外隆凸垂直距离在脑积水与非脑积水病例中分别<6 cm和>4 cm,且随前后径/宽度比增大,参考点需更高、入口点离枕外隆凸更远。结论认为不存在通用外部入口点,需按颅骨形态/比例分类并个体化徒手穿刺。
要点
- 理想轨迹的枕外隆凸垂直距离在脑积水病例中<6 cm,非脑积水病例中>4 cm。
- 前后径/宽度比增大时,参考点需更高,入口点离枕外隆凸更远。
- 更圆或长头型颅骨首选90°入路,尤其首次穿刺。
核心结论
- 不存在适用于所有病例的通用外部入口点,需按颅骨形态/比例分类并个体化徒手穿刺。
研究设计与样本
- 虚拟现实研究,使用50例人类尸颅骨测量前后径和宽度并分4型,另研究脑积水100例和正常MRI 50例,用OsiriX DICOM Viewer 3.9.4重建图像并估算轨迹。
主要发现
- 理想轨迹的枕外隆凸垂直距离在脑积水与非脑积水病例中分别<6 cm和>4 cm。
- 前后径/宽度比增大时,参考点需离鼻根更远,入口点离枕外隆凸距离也增加。
- 更圆或更長头型颅骨 dictates 90° approach 更优,尤其首次穿刺。
关键数值与推荐
- 理想轨迹的枕外隆凸垂直距离:脑积水病例<6 cm,非脑积水病例>4 cm。
- 更圆或长头型颅骨首选90°入路,尤其首次穿刺。
临床怎么用
- 临床徒手脑室穿刺应依据颅骨形态和前后径/宽度比个体化选择入口点和角度,而非固定单一入口。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Cannulation of lateral ventricles via a posterior approach is a common neurosurgical procedure. It is often believed that a single entry and fiducial point applies to all. No importance is given to skull shape variations, which can lead to wrong shunt positions and revisions. OBJECTIVE: A virtual-reality study was conducted to find the ideal entry point, ideal forehead fiducial point, and ideal angulation of the ventricular catheter and variations in these with changes in skull shapes. METHODS: Fifty human cadaveric skulls were used to measure anteroposterior (AP) diameter and width and to classify shape of skulls into 4 types. Hydrocephalus (100 cases) and normal magnetic resonance images (50 cases) were studied from a PACS (Picture Archiving and Communication System) database. An Osirix DICOM Viewer (3.9.4) was used to reconstruct the images and estimate the ideal, 90°, and midline shunt trajectory and correlate the same with AP/width ratios and skull shapes. RESULTS: Contrary to popular practice, the vertical distance from the inion for ideal trajectory placement was <6 cm and >4 cm in all shapes and ratio groups for hydrocephalus and nonhydrocephalus cases, respectively. As the AP/width ratio increases, the fiducial needs to be placed at a higher distance from the nasion and the distance of the entry point also increased from the inion. A rounder or more dolichocephalic skull dictates a 90° approach to be better, especially as the first pass. CONCLUSIONS: No magical external entry point uniformly applicable for all cases exists. Hence, there is a need to classify skulls according to shapes/ratios and to use a tailored approach for a freehand pass to cannulate the ventricles.
引用
- Deora H, Pruthi N, Rao KVLN, et al. Predicting the Ideal Ventricular Freehand Pass Trajectory Using Osirix Software and the Role of Occipital Shape Variations. World Neurosurg. 2020. PMID: 32454198. doi:10.1016/j.wneu.2020.05.146
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。