框架立体定向内镜第三脑室造瘘术:提高精度并减少并发症
研究假设颅骨表面解剖与颅内解剖的差异导致内镜第三脑室造瘘术(ETV)并发症,通过58例框架立体定向ETV患者的头颅CT三维重建,比较经典Kocher点与理想入点的位置差异。结果显示超过70%的理想钻孔点距Kocher点≥0.5 cm,冠状面和矢状面中位偏差分别为0.74 cm(P<0.01)和0.81 cm(P<0.0001),提示立体定向技术可提高精度并减少不必要的操作。
要点
- 经典Kocher点与理想ETV入点存在显著偏差,冠状面中位偏差0.74 cm,矢状面0.81 cm。
- 超过70%的理想钻孔点距Kocher点≥0.5 cm(冠状面和矢状面均如此)。
- 框架立体定向ETV可增加精度并减少不必要的手术操作,从而提高安全性。
核心结论
- 框架立体定向内镜技术通过增加精度和减少不必要的操作来提高第三脑室造瘘术的安全性。
研究设计与样本
- 对58例接受框架立体定向ETV患者的头颅CT扫描进行三维重建,比较理想入点与Kocher点的位置。
主要发现
- 超过70%的理想钻孔点在冠状面和矢状面均距Kocher点≥0.5 cm。
- 冠状面中位偏差0.74 cm(P<0.01),矢状面中位偏差0.81 cm(P<0.0001)。
临床怎么用
- 在ETV中可考虑使用框架立体定向技术来精确确定入点,以减少与操作相关的并发症。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Endoscopic third ventriculostomy (ETV) is a widely accepted treatment for obstructive hydrocephalus. For most practitioners, this procedure will be performed without navigation guidance. Without such guidance, the complications associated with the procedure have ranged from 1% to 8%. We hypothesized that the discrepancy between the surface bony anatomy and internal cranial anatomy contributes to the morbidities associated with ETV. We tested this hypothesis by comparing the position of the entry point defined by the classic Kocher's point relative to the ideal entry point that would result in no manipulation of the endoscope defined by frame-based stereotaxis. METHODS: The cranial computed tomography scan of 58 patients who had undergone frame-based stereotactic ETV was reformatted into 3-dimensional renderings. The location of this entry point was compared with the Kocher point, as determined by the external bony anatomy. RESULTS: Overall, >70% of the burr holes that provided an ideal trajectory to the third ventricle were ≥0.5 cm from the Kocher point in both the sagittal and the coronal planes. Median deviations of 0.74 and 0.81 cm in the coronal (P < 0.01) and sagittal (P < 0.0001) planes were observed. CONCLUSION: The use of stereotactic endoscopic techniques increase the safety of third ventriculostomy by adding precision and reducing otherwise unnecessary surgical maneuvering.
引用
- Chen CC, Freeman D, Warnke PC, et al. Frame-Based Stereotactic Endoscopic Third Ventriculostomy-Toward Improved Precision and Minimizing Morbidities. World Neurosurg. 2020. PMID: 32437981. doi:10.1016/j.wneu.2020.05.040
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。