文献速递功能神经外科神经重症

框架式与无框架立体定向SEEG电极植入的精度与准确性比较

Superior accuracy and precision of SEEG electrode insertion with frame-based vs. frameless stereotaxy methods.
PubMed 文献 · Acta Neurochir (Wien) · 2020-05-26

该回顾性研究比较了CRW框架式与StealthStation S7无框架立体定向方法在颞叶SEEG靶点(杏仁核与海马头)的电极植入精度。23例患者共81根电极,框架式组靶点命中率更高(0%脱靶 vs 无框架组18%),平均欧氏距离误差更小(杏仁核7.1 mm vs 11.0 mm,海马头8.5 mm vs 12.4 mm,均p<0.001),两组均无出血或临床并发症。

要点

  • 框架式SEEG电极植入的靶点命中率显著高于无框架导航系统。
  • 框架式方法在杏仁核与海马头的平均误差均显著小于无框架方法。
  • 两组均未发生出血或临床并发症。

核心结论

  • 基于本系列数据,框架式SEEG植入比使用导航引导系统的无框架植入显著更准确、更精确,并产生更多临床有用的电极触点。

研究设计与样本

  • 回顾性研究,纳入一家四级癫痫中心接受SEEG植入的患者,比较CRW框架式与StealthStation S7无框架导航系统的电极植入。
  • 共识别23例患者的81根SEEG电极,其中杏仁核靶点40根、海马头靶点41根;框架式组36根,无框架组45根。
  • 通过融合术前MRI与术后CT计算电极尖端坐标,与预定理想坐标比较误差和方向偏差。

主要发现

  • 无框架组45根电极中8根(18%)未命中靶点且临床无用,框架式组36根中0根(0%)未命中。
  • 杏仁核靶点实际与理想电极尖端坐标的平均欧氏距离:无框架组11.0 mm vs 框架式组7.1 mm(p < 0.001)。
  • 海马头靶点平均欧氏距离:无框架组12.4 mm vs 框架式组8.5 mm(p < 0.001)。
  • 两组均无出血或临床并发症。

临床怎么用

  • 对于未使用机器人植入的中心,框架式立体定向方法在常见颞叶SEEG靶点(杏仁核、海马头)上可能提供更高的准确性和 precision。
  • 无框架导航系统植入SEEG时需注意其较高的脱靶风险(本系列中18%电极临床无用)。

局限性

  • 回顾性研究设计,样本量有限(23例患者、81根电极)。
  • 仅聚焦两个常见颞叶靶点(杏仁核与海马头),结论外推至其他靶点需谨慎。
  • 单中心经验,结果可能受操作者技术与设备条件影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Stereotactic electroencephalography (SEEG) has largely become the preferred method for intracranial seizure localization in epileptic patients due to its low morbidity and minimally invasive approach. While robotic placement is gaining popularity, many centers continue to use manual frame-based and frameless methods for electrode insertion. However, it is unclear how these methods compare in regard to accuracy, precision, and safety. Here, we aim to compare frame-based insertion using a CRW frame (Integra®) and frameless insertion using the StealthStation™ S7 (Medtronic®) navigation system for common temporal SEEG targets. METHODS: We retrospectively examined electrode targets in SEEG patients that were implanted with either frame-based or frameless methods at a level 4 epilepsy center. We focused on two commonly used targets: amygdala and hippocampal head. Stealth station software was used to merge pre-operative MR with post-operative CT images for each patient, and coordinates for each electrode tip were calculated in relation to the midcommissural point. These were compared to predetermined ideal coordinates in regard to error and directional bias. RESULTS: A total of 81 SEEG electrodes were identified in 23 patients (40 amygdala and 41 hippocampal head). Eight of 45 electrodes (18%) placed with the frameless technique and 0 of 36 electrodes (0%) placed with the frame-based technique missed their target and were not clinically useful. The average Euclidean distance comparing actual to ideal electrode tip coordinates for frameless vs. frame-based techniques was 11.0 mm vs. 7.1 mm (p < 0.001) for the amygdala and 12.4 mm vs. 8.5 mm (p < 0.001) for the hippocampal head, respectively. There were no hemorrhages or clinical complications in either group. CONCLUSIONS: Based on this series, frame-based SEEG insertion is significantly more accurate and precise and results in more clinically useful electrode contacts, compared to frameless insertion using a navigation guidance system. This has important implications for centers not currently using robotic insertion.

来源:Acta Neurochir (Wien),查看原文。版权归原作者所有。

引用

  1. Girgis F, Royz E, Kennedy J, et al. Superior accuracy and precision of SEEG electrode insertion with frame-based vs. frameless stereotaxy methods. Acta Neurochir (Wien). 2020. PMID: 32458403. doi:10.1007/s00701-020-04427-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。