基于个体化解剖靶向的VIM-cZI脑深部电刺激治疗特发性震颤
该研究针对33例难治性特发性震颤患者,采用基于个体化解剖标志的VIM-cZI脑深部电刺激电极植入靶向方案,随访31.1±18.4个月。结果显示震颤平均改善79.7%±22.4%且保持稳定,未观察到出血并发症,提示该靶向方法可行、安全且震颤结局良好。
要点
- 个体化解剖靶向VIM-cZI脑深部电刺激可显著改善特发性震颤。
- 震颤平均改善79.7%±22.4%,随访期间保持稳定。
- 分析组未观察到出血并发症,安全性可接受。
核心结论
- 基于个体化解剖的VIM-cZI靶向方案可行、安全,并与良好的震颤结局相关。
研究设计与样本
- 33例特发性震颤患者接受VIM-cZI电极植入,靶向基于个体化解剖方案,随访31.1±18.4个月。
- 间接靶向根据解剖标志调整,参考线为平分红核及同侧底丘脑的线。
- 通过MATLAB Lead-DBS工具箱在蒙特利尔神经学研究所空间重建电极获取活跃触点坐标。
主要发现
- 震颤平均改善79.7%±22.4%,在整个随访期间保持稳定。
- 末次术后随访活跃触点平均MNI坐标为:intercommissural线外侧15.5±1.6 mm,前连合后方15.3±1.8 mm,intercommissural平面下方1.4±2.9 mm。
- 分析组未观察到出血并发症。
临床怎么用
- 对于难治性特发性震颤,可考虑采用基于个体化解剖标志的VIM-cZI靶向方案进行脑深部电刺激电极植入。
- 术后可通过电极重建确认活跃触点位置,辅助评估靶向准确性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Deep brain stimulation of the ventral intermediate nucleus (VIM) or caudal zona incerta (cZI) is effective for refractory essential tremor (ET). To refine stereotactic planning for lead placement, we developed a unique individualized anatomy-based planning protocol that targets both the VIM and the cZI in patients with ET. METHODS: 33 patients with ET underwent VIM-cZI lead implantation with targeting based on our protocol. Indirect targeting was adjusted based on anatomic landmarks as reference lines bisecting the red nuclei and ipsilateral subthalamus. Outcomes were evaluated through the follow-up of 31.1 ± 18.4 months. Active contact coordinates were obtained from reconstructed electrodes in the Montreal Neurological Institute space using the MATLAB Lead-DBS toolbox. RESULTS: Mean tremor improvement was 79.7% ± 22.4% and remained stable throughout the follow-up period. Active contacts at last postoperative visit had mean Montreal Neurological Institute coordinates of 15.5 ± 1.6 mm lateral to the intercommissural line, 15.3 ± 1.8 mm posterior to the anterior commissure, and 1.4 ± 2.9 mm below the intercommissural plane. No hemorrhagic complications were observed in the analyzed group. CONCLUSIONS: Individualized anatomy-based VIM-cZI targeting is feasible and safe and is associated with favorable tremor outcomes.
引用
- Diaz A, Cajigas I, Cordeiro JG, et al. Individualized Anatomy-Based Targeting for VIM-cZI DBS in Essential Tremor. World Neurosurg. 2020. PMID: 32438003. doi:10.1016/j.wneu.2020.04.240
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。