IDH突变胶质瘤皮质脊髓束微结构改变与运动皮层兴奋性的相关性研究
这项前瞻性病例对照研究纳入10例IDH突变胶质瘤患者和10名健康对照,采用球面去卷积(SD)纤维示踪和导航经颅磁刺激(nTMS)评估皮质脊髓束微结构与运动皮层兴奋性。结果显示肿瘤同侧HMOA降低(p=0.028)、静息运动阈值(rMT)升高(p=0.038),且SD弥散参数与rMT正相关,HMOA与rMT的半球间差异相关(p=0.007)。
要点
- SD纤维示踪可显示IDH突变胶质瘤患者皮质脊髓束微结构异常。
- 肿瘤同侧HMOA降低且rMT升高,提示微结构与兴奋性改变相关。
- SD弥散参数与nTMS功能测量相关,支持多模态评估价值。
核心结论
- SD纤维示踪能显示IDH1突变胶质瘤患者皮质脊髓束内与nTMS功能异常相关的微结构异常。
研究设计与样本
- 采用3-T MRI采集弥散加权图像,并行弥散张量成像和SD纤维示踪的确定性追踪。
- 使用导航脑刺激系统在运动热点处给予TMS脉冲并记录运动诱发电位(MEP)。
- 采用Spearman秩相关分析弥散指标与功能测量之间的相关性。
主要发现
- SD纤维示踪测量的HMOA在胶质瘤同侧半球较低(p=0.028)。
- 胶质瘤同侧半球rMT显著高于对侧半球(p=0.038)。
- 除MEP平均波幅外(p=0.001),胶质瘤对侧的所有测量与健康对照相似。
- SD纤维示踪的平均弥散率和轴向弥散率与胶质瘤同侧半球rMT正相关(p=0.02和0.006)。
- 胶质瘤患者HMOA与rMT的半球间差异相关(p=0.007)。
临床怎么用
- 可联合SD纤维示踪与nTMS评估IDH突变胶质瘤患者皮质脊髓束微结构与运动皮层兴奋性改变。
- 关注肿瘤同侧HMOA降低及rMT升高,辅助识别皮质脊髓束受累。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: This prospective case-control study was conducted to examine whether spherical deconvolution (SD) can unveil microstructural abnormalities in the corticospinal tract (CST) caused by IDH-mutant gliomas. To determine the significance of abnormal microstructure, the authors investigated the correlation between diffusion parameters and neurophysiological data collected with navigated transcranial magnetic stimulation (nTMS). METHODS: Twenty participants (10 patients and 10 healthy controls) were recruited. Diffusion-weighted images were acquired on a 3-T MRI scanner using a cardiac-gated single-shot spin echo echo-planar imaging multiband sequence (TE 80 msec, TR 4000 msec) along 90 diffusion directions with a b-value of 2500 sec/mm2 (FOV 256 × 256 mm). Diffusion tensor imaging tractography and SD tractography were performed with deterministic tracking. The anterior portion of the ipsilateral superior peduncle and the precentral gyrus were used as regions of interest to delineate the CST. Diffusion indices were extracted and analyzed for significant differences between hemispheres in patients and between patient and control groups. A navigated brain stimulation system was used to deliver TMS pulses at hotspots at which motor evoked potentials (MEPs) for the abductor pollicis brevis, first digital interosseous, and abductor digiti minimi muscles are best elicited in patients and healthy controls. Functional measurements such as resting motor threshold (rMT), amplitude of MEPs, and latency of MEPs were noted. Significant differences between hemispheres in patients and between patients and controls were statistically analyzed. The Spearman rank correlation was used to investigate correlations between diffusion indices and functional measurements. RESULTS: The hindrance modulated orientational anisotropy (HMOA), measured with SD tractography, is lower in the hemisphere ipsilateral to glioma (p = 0.028). The rMT in the hemisphere ipsilateral to a glioma is significantly greater than that in the contralateral hemisphere (p = 0.038). All measurements contralateral to the glioma, except for the mean amplitude of MEPs (p = 0.001), are similar to those of healthy controls. Mean diffusivity and axial diffusivity from SD tractography are positively correlated with rMT in the hemisphere ipsilateral to glioma (p = 0.02 and 0.006, respectively). The interhemispheric difference in HMOA and rMT is correlated in glioma patients (p = 0.007). CONCLUSIONS: SD tractography can demonstrate microstructural abnormality within the CST of patients with IDH1-mutant gliomas that correlates to the functional abnormality measured with nTMS.
引用
- Mirchandani AS, Beyh A, Lavrador JP, et al. Altered corticospinal microstructure and motor cortex excitability in gliomas: an advanced tractography and transcranial magnetic stimulation study. J Neurosurg. 2020. PMID: 32357341. doi:10.3171/2020.2.JNS192994
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。