新型脑肿瘤手术训练模拟器的开发与初步评估
本研究基于人颅骨CT三维打印结合小牛脑组织与增强现实技术构建新型神经外科手术模拟器,并设置四种手术场景。29名参与者至少完成一种场景并填写问卷与访谈,颅骨与脑组织的视觉和感官真实感评为「很好」,肿瘤模型评为「良好」,但小牛脑体积小、保存期有限及无法模拟出血为主要缺陷。
要点
- 3D打印颅骨联合真实脑组织可提供很好的手术真实感。
- 模拟器支持导航、增强现实、荧光及外视镜手术训练。
- 小牛脑体积小、保存期短及无法模拟出血是主要局限。
核心结论
- 3D打印与真实脑组织结合可提供与真实手术高度相似的手术场景。
- 该模拟器支持多种手术技能训练及图像引导、荧光引导、外视镜手术和机器人技术训练。
研究设计与样本
- 基于人颅骨CT扫描3D打印颅底与颅盖并配备人工硬脑膜。
- 将小牛大脑半球置于颅盖凸面并注射由明胶、水和荧光素组成的肿瘤块。
- 共29名参与者至少完成一种训练场景并填写5项Likert式问卷及定性访谈。
主要发现
- 颅骨与脑组织的视觉和感官真实感评为「很好」。
- 肿瘤模型的感官和视觉真实感评为「良好」。
- 对模型的总体满意度及显微镜和神经外科器械适用性评为「很好」。
- 小牛脑体积小、保存期有限及因缺乏灌注无法模拟出血为显著缺陷。
关键数值与推荐
- 共设置四种手术场景:简单肿瘤切除、复杂肿瘤切除、经钻孔导航活检及乙状窦后开颅。
- 训练中可用神经导航、增强现实、荧光及目镜与屏幕(外视镜)手术。
临床怎么用
- 可用于神经外科手术技能训练及图像与荧光引导、外视镜手术和机器人技术训练。
局限性
- 小牛脑体积小。
- 小牛脑保存期有限。
- 因缺乏灌注无法模拟出血。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Increasing technico-manual complexity of procedures and time constraints necessitates effective neurosurgical training. For this purpose, both screen- and model-based simulations are under investigation. Approaches including 3D printed brains, gelatin composite models, and virtual environments have already been published. However, quality of brain surgery simulation is limited due to discrepancies in visual and haptic experience. Similarly, virtual training scenarios are still lacking sufficient real-world resemblance. In this study, we introduce a novel simulator for realistic neurosurgical training that combines real brain tissue with 3D printing and augmented reality. METHODS: Based on a human CT scan, a skull base and skullcap were 3D printed and equipped with an artificial dura mater. The cerebral hemispheres of a calf's brain were placed in the convexity of the skullcap and tumor masses composed of aspic, water, and fluorescein were injected in the brain. The skullcap and skull base were placed on each other, glued together, and filled up with an aspic water solution for brain fixation. Then, four surgical scenarios were performed in the operating room as follows: (1) simple tumor resection, (2) complex tumor resection, (3) navigated biopsy via burr hole trepanation, and (4) retrosigmoidal craniotomy. Neuronavigation, augmented reality, fluorescence, and ocular-as well as screen-based (exoscopic)-surgery were available for the simulator training. A total of 29 participants performed at least one training scenario of the simulator and completed a 5-item Likert-like questionnaire as well as qualitative interviews. The questionnaire assessed the realism of the tumor model, skull, and brain tissue as well as the capability for training purposes. RESULTS: Visual and sensory realism of the skull and brain tissue were rated,"very good," while the sensory and visual realism of the tumor model were rated "good." Both overall satisfaction with the model and eligibility of the microscope and neurosurgical instruments for training purposes were rated with "very good." However, small size of the calf's brain, its limited shelf life, and the inability to simulate bleedings due to the lack of perfusion were significant drawbacks. CONCLUSION: The combination of 3D printing and real brain tissue provided surgical scenarios with very good real-life resemblance. This novel neurosurgical model features a versatile setup for surgical skill training and allows for efficient training of technological support like image and fluorescence guidance, exoscopic surgery, and robotic technology.
引用
- Grosch AS, Schröder T, Schröder T, et al. Development and initial evaluation of a novel simulation model for comprehensive brain tumor surgery training. Acta Neurochir (Wien). 2020. PMID: 32385637. doi:10.1007/s00701-020-04359-w
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。