杂交手术室内动脉超选择性吲哚菁绿视频血管造影在脑动静脉畸形手术中的疗效
该研究在杂交手术室对13例脑动静脉畸形患者行术中动脉内超选择性吲哚菁绿视频血管造影,克服了静脉注射ICG残留的局限。结果显示动脉内ICG能清晰识别供血动脉、畸形团和引流静脉,并评估血流动力学变化。作者认为该方法优于静脉ICG视频血管造影,尤其结合Flow 800分析时。
要点
- 动脉内ICG视频血管造影可清晰显示脑AVM的供血动脉、畸形团和引流静脉。
- ICG在供血动脉、引流静脉和所有血管中的洗脱时间分别为4.4±1.3秒、9.2±3.5秒和20.9±3.4秒。
- Flow 800分析可简化并辅助评估畸形团血流动力学变化。
核心结论
- 动脉内ICG视频血管造影在脑AVM手术中比静脉ICG视频血管造影更有用,尤其在识别供血动脉、畸形团、引流静脉及评估畸形团血流动力学方面有效。
研究设计与样本
- 本研究为单中心病例系列,纳入13例脑AVM患者,在杂交手术室内行术中动脉内超选择性ICG视频血管造影,通过导管向对比剂中追加注射ICG。
主要发现
- 分离前造影在13例中的12例可视化了供血动脉,12例可视化了畸形团,所有病例均可视化了引流静脉。
- 完全分离畸形团后,所有病例的引流静脉均未见ICG充盈。
- ICG洗脱时间:供血动脉4.4±1.3秒,引流静脉9.2±3.5秒,所有血管20.9±3.4秒。
- 在9例中确认了分离过程中畸形团血流减少,且因各时间段很短而易于识别。
- Flow 800分析提供的彩色编码可视化和客观数据强化了上述发现。
关键数值与推荐
- 分离前造影中供血动脉可视化12/13例,畸形团可视化12/13例,引流静脉可视化13/13例。
- 完全分离后引流静脉ICG充盈0/13例。
- ICG洗脱时间:供血动脉4.4±1.3秒,引流静脉9.2±3.5秒,所有血管20.9±3.4秒。
- 分离过程中畸形团血流减少确认9/9例。
临床怎么用
- 在杂交手术室行脑AVM手术时,可经导管动脉内注射ICG行视频血管造影,以重复评估供血动脉、畸形团和引流静脉。
- 利用Flow 800分析可辅助客观评估畸形团血流动力学变化。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Although intravenous indocyanine green (ICG) videoangiography has been reported to be useful when applied to cerebral arteriovenous malformation (AVM) surgery, the ICG that remains after the procedure makes it difficult to understand the anatomy, to evaluate nidus blood flow changes, and to repeat ICG videoangiography within a short time. Intraarterial ICG videoangiography has emerged as a way to overcome these limitations. The current study presents the results of intraarterial ICG videoangiography undertaken in patients with cerebral AVMs. METHODS: Intraarterial ICG videoangiography was performed in 13 patients with cerebral AVMs. Routine intraoperative digital subtraction angiography at the authors' institution is performed in a hybrid operating room during AVM surgery and includes the added step of injecting ICG to the contrast medium that is administered through a catheter. RESULTS: Predissection studies were able to visualize the feeder in 12 of 13 cases. The nidus was visualized in 12 of 13 cases, while the drainer was visualized in all cases. After total dissection of the nidus, there was no ICG filling in the drainers found in any of the cases. Washout of the ICG took 4.4 ± 1.3 seconds in the feeders, 9.2 ± 3.5 seconds in the drainers, and 20.9 ± 3.4 seconds in all of the vessels. Nidus flow reduction was confirmed during dissection in 9 of 9 cases. Flow reduction was easy to recognize due to each span being very short. Color-encoded visualization and objective data obtained by Flow 800 analysis reinforced these findings. CONCLUSIONS: The results showed that intraarterial ICG videoangiography was more useful than intravenous ICG videoangiography in cerebral AVM surgery. This was especially effective in the identification of the feeder, nidus, and drainer and in the assessment of the flow dynamics of the nidus. Use of Flow 800 made it simpler and easier to evaluate these findings.
引用
- Shimada K, Yamaguchi T, Miyamoto T, et al. Efficacy of intraarterial superselective indocyanine green videoangiography in cerebral arteriovenous malformation surgery in a hybrid operating room. J Neurosurg. 2020. PMID: 32442970. doi:10.3171/2020.3.JNS20319
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。