文献速递脊柱脊髓外科神经重症

微创经椎间孔腰椎椎间融合术中应用过氧化氢后发生氧栓塞与颅内积气:一例病例报告及文献综述

Oxygen Embolism and Pneumocephalus After Hydrogen Peroxide Application During Minimally Invasive Transforaminal Lumbar Interbody Fusion Surgery: A Case Report and Literature Review.
PubMed 文献 · World Neurosurg · 2020-03-14

一例40岁女性因L4-5腰椎椎管狭窄行微创经椎间孔腰椎椎间融合术,过氧化氢冲洗后立即出现低血压、低氧及呼气末二氧化碳分压下降,术后仍昏迷,CT示右侧额叶颅内积气及多发脑梗死灶。作者认为膝胸卧位或硬膜撕裂时,尤其闭合腔手术创面,应避免使用未稀释过氧化氢溶液;冲洗后出现上述表现应高度怀疑氧栓塞。

要点

  • 过氧化氢冲洗后立即出现低血压、低氧和呼气末二氧化碳分压下降,应高度怀疑氧栓塞。
  • 膝胸卧位或硬膜撕裂时,尤其闭合腔手术创面,应避免使用未稀释过氧化氢溶液。
  • 术后CT可表现为颅内积气及多发脑梗死灶。

核心结论

  • 膝胸卧位或硬膜撕裂时,尤其闭合腔手术创面,应避免使用未稀释过氧化氢溶液。
  • 过氧化氢冲洗后立即出现低血压、低氧及呼气末二氧化碳分压下降时,应高度怀疑氧栓塞。

研究设计与样本

  • 病例报告及文献综述:一例40岁女性L4-5腰椎椎管狭窄患者,在外院行微创经椎间孔腰椎椎间融合术。

主要发现

  • 过氧化氢冲洗后立即出现低血压、低氧及呼气末二氧化碳分压下降。
  • 术后可拔管但仍昏迷,术后CT示右侧额叶颅内积气及多发脑梗死灶。

临床怎么用

  • 作者认为,膝胸卧位或硬膜撕裂时,尤其闭合腔手术创面,应避免使用未稀释过氧化氢溶液;冲洗后出现低血压、低氧及呼气末二氧化碳分压下降应高度怀疑氧栓塞。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Hydrogen peroxide (H2O2) solution is commonly used to irrigate wounds because of its hemostatic and antiseptic properties. Previous studies suggest that H2O2 can result in toxicity to keratinocytes and fibroblasts, but complications after H2O2 application, including oxygen embolism, which is one of the most severe, have rarely been reported. CASE DESCRIPTION: A 40-year-old woman was diagnosed with L4-5 lumbar spinal stenosis and subsequently underwent minimally invasive transforaminal lumbar interbody fusion treatment at another hospital. Hypotension, hypoxia, and a decrease in end-tidal carbon dioxide pressure occurred immediately after H2O2 irrigation. After the operation, she was able to be extubated but remained comatose. Postoperative computed tomography scan revealed intracranial air trapping in the right frontal lobe and multiple cerebral infarction foci. CONCLUSIONS: When using a knee-prone surgical position or in cases of dural laceration, the application of undiluted H2O2 solution should be avoided, especially in a surgical wound within a closed cavity. When hypotension, hypoxia, and a decrease in end-tidal carbon dioxide pressure occur immediately after H2O2 irrigation, oxygen embolism should be strongly suspected.

来源:World Neurosurg,查看原文。版权归原作者所有。

引用

  1. Zou P, Yang JS, Wang XF, et al. Oxygen Embolism and Pneumocephalus After Hydrogen Peroxide Application During Minimally Invasive Transforaminal Lumbar Interbody Fusion Surgery: A Case Report and Literature Review. World Neurosurg. 2020. PMID: 32179190. doi:10.1016/j.wneu.2020.03.035

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。