扭转钻与螺栓系统对比标准环钻与隧道化放置脑室外引流管的准确性与并发症率:一项基于人群的回顾性研究
该单中心回顾性观察研究纳入2008至2018年272例接受脑室外引流(EVD)的患者,比较螺栓系统EVD(61例)与标准EVD(211例)的准确性与并发症。结果显示两组在置管准确性和并发症率上无差异,但螺栓组翻修手术率更低(8.2% vs 21.5%)、手术时间更短(平均16.5 vs 28.8分钟),而首次置管尝试次数更多(平均1.72±1.2 vs 1.32±0.8)。
要点
- 螺栓系统EVD与标准EVD在置管准确性和术后并发症率上无差异。
- 螺栓组翻修手术率低于标准组(8.2% vs 21.5%,p=0.020)。
- 螺栓组手术时间短于标准组(平均16.5 vs 28.8分钟,p<0.001),但首次置管尝试次数更多(1.72±1.2 vs 1.32±0.8,p=0.017)。
核心结论
- 两种方法在置管准确性和术后并发症率上相似,翻修手术需求和手术时间的差异 favoring 螺栓组,螺栓组首次置管尝试次数略多,可能反映扭转钻入路角度校正灵活性较低。
研究设计与样本
- 回顾性观察研究,单中心设置,2008年至2018年,共272例患者接受EVD(螺栓EVD 61例,标准EVD 211例),使用Kakarla评分系统评估置管准确性,并记录术后并发症、手术时间和置管尝试次数。
主要发现
- 翻修手术率:螺栓系统组8.2% vs 标准方法组21.5%(p=0.020)。
- 手术时间:螺栓系统组平均16.5分钟 vs 标准方法组28.8分钟(95% CI 7.64, 16.8,p<0.001)。
- 首次EVD成功置管尝试次数:螺栓系统组平均1.72±1.2 vs 标准方法组1.32±0.8(p=0.017)。
- 置管准确性或并发症率无差异。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: An external ventricular drain (EVD) is typically indicated in the presence of hydrocephalus and increased intracranial pressure (ICP). Procedural challenges have prompted the development of different methods to improve accuracy, safety, and logistics. OBJECTIVES: EVD placement and complications rates were compared using two surgical techniques; the standard method (using a 14-mm trephine burrhole with the EVD tunnelated through the skin) was compared to a less invasive method (EVD placed through a 2.7-3.3-mm twist drill burrhole and fixed to the bone with a bolt system). METHODS: Retrospective observational study in a single-centre setting between 2008 and 2018. EVD placement was assessed using the Kakarla scoring system. We registered postoperative complications, surgery duration and number of attempts to place the EVD. RESULTS: Two hundred seventy-two patients received an EVD (61 bolt EVDs, 211 standard EVDs) in the study period. Significant differences between the bolt system and the standard method were observed in terms of revision surgeries (8.2% vs. 21.5%, p = 0.020), surgery duration (mean 16.5 vs. 28.8 min, 95% CI 7.64, 16.8, p < 0.001) and number of attempts to successfully place the first EVD (mean 1.72 ± 1.2 vs. 1.32 ± 0.8, p = 0.017). There were no differences in accuracy of placement or complication rates. CONCLUSIONS: The two methods show similar accuracy and postoperative complication rates. Observed differences in both need for revisions and surgery duration favoured the bolt group. Slightly, more attempts were needed to place the initial EVD in the bolt group, perhaps reflecting lower flexibility for angle correction with a twist drill approach.
引用
- Mansoor N, Madsbu MA, Mansoor NM, et al. Accuracy and complication rates of external ventricular drain placement with twist drill and bolt system versus standard trephine and tunnelation: a retrospective population-based study. Acta Neurochir (Wien). 2020. PMID: 32020298. doi:10.1007/s00701-020-04247-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。